Fire Sentry FS17X Installation Manual And Operating Manual Download Page 2

 

 

 

Fire Sentry Corporation 

Document No. 6178-007 - Rev. F 

©

 Copyright 2012 

All Rights Reserved 

Fire Sentry Corporation 

23311 La Palma Avenue 

Yorba Linda, California 92887 

Tel:   (714) 694-2700 
Fax:   (714) 694-2701 

www.firesentry.com 

 

Read and understand this manual before 

installing or operating equipment. 

 

No part of this document may be copied or reproduced without the express 

written permission of Fire Sentry Corporation. 

 

This manual is subject to change without notice. 

 
 

ACCTTL,  ALERT-1,  ALARM-2,  ALERT-1:  ALARM  2,  ALERT-1:  ALARM-2,  ATAG,  Clean 
Room Sentry, COP-i, Complete Optical Path Integrity, CM1, CM1-A, DartLogic, FireLogic, Fire 
Signature Analysis, FireBusI, FireBusII, FirePic, FirePicII, FirePicIII, FirePix, FirePicture, FSC, 
Fire  Sentry  Corporation,  Fire  Sentry  Corp.,  FSX,  All  FSX  Nomenclature  Variations  (such  as:  
FS2,  FS2X,  FS2X,  FS3,  FS3X,  FS3X,  FS4,  FS4X,  FS4X,  FS5,  FS5X,  FS5X,  FS6,  FS6X, 
FS6X,  FS7,  FS7X,  FS7X,  FS8,  FS8X,  FS8X,  FS9,  FS9X,  FS9X,  FS10X,  FS10X,  FS11, 
FS11X, FS11X, FS12,  FS12X,  FS12X, FS14, FS14X, FS14X, FS15, FS15X, FS15X, FS16, 
FS16X,  FS16X,  FS17,  FS17X,  FS17X,  FS18,  FS18X,  FS18X,  FS19,  FS19X,  FS19X,  FS20, 
FS20X,  FS20X,  FS24,  FS24X,  FS24X,  FS24XN,  FS24XN,  FS26,  FS26X,  FS26X,  FS26XN, 
FS26XN, FS7-2173-2RP, FS System 7, FS System 10, FS7-2173, FS7-2173-RP, FS2000, FS 
System  2000,  High  Speed  Flame  &  Surveillance  Detector,  Multi-Spectrum  QuadBand  Triple 
IR,  Multi-Spectrum  TriBand,  Multi-Spectrum  Tri-Band,  Near  Band  Infrared,  Near  Band  IR, 
NearBand  IR,  QuadBand  IR,  Room  Sentry,  RS,  RS2,  SM2,  SM3,  SS,  SS2,  SS2X,  SS2-A, 
SS3, SS3-A, SS3X, SS4, SS4-A, SS4X, SnapShot, SLR-BIT, SuperBus, SuperSentry, System 
2000, Tri-Mode Plot, QuadBand Triple IR Plus, TriBand, Tri-Band, “FS & FSC triangle logo’s”, 
WBIR, Wide Band Infrared, WideBand IR, Wide Band IR 

 

are Trademarks of  Fire Sentry Corporation, Yorba Linda, California. 

 

©Copyright 1998 - 2012 by Fire Sentry Corporation 

Summary of Contents for FS17X

Page 1: ...t 2012 All Rights Reserved Fire Sentry Corporation 23311 La Palma Avenue Yorba Linda California 92887 Telephone 714 694 2700 Fax 714 694 2701 www firesentry com FS17X WideBand IRTM Multi Spectral Infr...

Page 2: ...ns such as FS2 FS2X FS2X FS3 FS3X FS3X FS4 FS4X FS4X FS5 FS5X FS5X FS6 FS6X FS6X FS7 FS7X FS7X FS8 FS8X FS8X FS9 FS9X FS9X FS10X FS10X FS11 FS11X FS11X FS12 FS12X FS12X FS14 FS14X FS14X FS15 FS15X FS1...

Page 3: ...pecifications 2 1 2 5 Area Classification 2 1 3 Features Benefits 3 1 4 Applications 3 SECTION 2 INSTALLATION 4 2 1 Mounting Instructions 4 2 2 Detector Connections 5 2 3 Installation Practices 8 2 4...

Page 4: ...d IP67 dust tight leak proof and water tight to 1 meter Figure 1 1 FS17X Detector FS17X Connections The Model FS17X uses an eight 8 conductor Standard Cable or an optional eight 8 conductor Cable with...

Page 5: ...Lens 4 0 mA 0 6 mA Normal Safe no Fault no Fire 20 0 mA 0 6 mA Fireball or Fire ALARM 20 0 mA 0 6 mA Fire ALARM or Verified Fire ALARM Cable Eight 8 Conductor 24 AWG or fourteen 14 Conductor 24 AWG M...

Page 6: ...M current 2 11 W Multiple Detector output options for a variety of industrial applications Up to 32 unique digital communication addresses when RS 485 communication is used Optional RS 485 output avai...

Page 7: ...Physical obstructions between a fire and the Detector may cause the fire to be undetected 4 The rugged stable and calibrated Polypropylene Swivel Mount SM17 is designed specifically for the FS17X Det...

Page 8: ...Response Fireball Relay COM COMmon Fire Verification Relay COM COMmon Current Sinking 4 20mA Orange Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally...

Page 9: ...RS 485 Quick Response Fireball Relay COM COMmon Fire Verification Relay COM COMmon Current Sinking 4 20mA Red Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally Open Fire ALARM Relay N...

Page 10: ...nal A Blue Fire ALARM Relay Terminal B Brown White Fire ALARM Relay Terminal A loop through Blue White Fire ALARM Relay Terminal B loop through Yellow Fire ALERT Relay Terminal A Orange Fire ALERT Rel...

Page 11: ...ockwise circular motion signifying the microprocessors are successfully checking out the sensors and electronics in the Detector Module 2 4 Start Up and Commissioning ATTENTION FSX Power Up After the...

Page 12: ...ensuring all the system wiring and cabling and system control panel s are properly installed Additionally using an external test lamp eliminates the following Detector conditions 1 The fire or flame...

Page 13: ...ding its pushbutton While watching the red ALARM LED on the face of the Detector slowly move the Test Lamp s boresight to ensure the Detector receives its full intensity UNOTE Practicing this techniqu...

Page 14: ...isible Band and NearBand IR are used primarily to further discriminate against non fire false alarm sources As with all Fire Sentry Corporation Detectors the Model FS17X Detector senses radiant energy...

Page 15: ...s every 10 seconds See Figure 3 1 for the location of the Blue LED Normal Operation is defined as the Detector with 24 Vdc applied and no ALARM or Fault conditions are present Flashes LED Status 1 Blu...

Page 16: ...rt OR Moisture is inside of the Detector Housing Contact Fire Sentry Corporation to speak with a Technical Representative 5 Yellow High or Low Temperature Fault Less than 40 C or Greater than 60 C Zon...

Page 17: ...ting should be performed using the correct Fire Sentry Test Lamp to ensure the integrity of the entire fire protection system see Note in Section 2 4 and Section 4 3 Clean the FS17X Detector window Ea...

Page 18: ...time inconvenience commercial loss lost profits or savings or other incidental special or consequential damages arising out of or in connection with the use or inability to use such Product THIS WARRA...

Page 19: ...gral Cable 8 conductor Kalrez O Ring P Phoenix 8 Pin Connector Relay Contact Fault N C Normally Energized Non Latching 1 Fire Relays N O Normally De Energized Non Latching 2 Fire Relays N O Normally D...

Page 20: ...ength 1 3 meters 10 feet 2 6 meters 20 feet Standard 3 12 meters 40 feet 4 18 meters 60 feet 5 24 meters 80 feet F O Ring K Kalrez O Ring V Viton O Ring Standard E Relay Mode N Non Latching Standard D...

Page 21: ...or is aimed properly that its view of the fire scene has not been blocked by something such as a newly installed pipe or duct storage box parked vehicle etc and its ALARM outputs are functioning prope...

Page 22: ...v F Copyright 2012 All Rights Reserved Page 19 4 4 Drawings 4 4 1 Outline and Dimensions Figure 4 3 Outline Dimesional Drawing for Model FS17X Figure 4 4 Outline Dimesional Drawing for SM17 Swivel Mou...

Page 23: ...ill Energize during ALARM conditions 3 Fault relay contacts shown with no electrical power applied During normal operation and with no Fault this relay will De Energize and the N O Normally Open conta...

Page 24: ...normal operation and with no Fault this relay will De Energize and the N O Normally Open contacts will close 4 At the Fire Alarm or Process Panel connect a jumper between 24 Vdc Supply and 4 20mA Figu...

Page 25: ...will Energize during ALARM conditions 3 Fault relay contacts shown with no electrical power applied During normal operation and with no Fault this relay will De Energize and the N O Normally Open con...

Page 26: ...ring normal operation and with no Fault this relay will De Energize and the N O Normally Open contacts will close 5 At the Fire Alarm or Process Panel connect a jumper between 24 Vdc Supply and 4 20mA...

Page 27: ...ault Relay Terminal A contact to B during Normal Operation Purple Fault Relay Terminal B contact to A during Normal Operation Brown Fire Alarm Relay Terminal A Blue Fire Alarm Relay Terminal B Brown w...

Page 28: ...Fire Verification 1 5 11 Fireball 1 2 5 FireBusII 3 5 11 12 FS17X G 5 11 FS17X R 11 FS17X S 5 11 FSIM 10 H Hazardous Location s 1 High Sensitivity 2 I Input Voltage Range 2 Installation 4 7 Introducti...

Page 29: ...Copyright 2012 All Rights Reserved Page 26 INDEX continued T Technical Specifications 2 Test Lamp 17 TL 1055X 7 9 13 17 TL 2055X 7 9 13 17 Tubing 15 16 Twin Microprocessors 3 V Verified Fire 2 VIS 2 V...