Heater Location
The heater is primarily for outdoor use only (see
attached diagrammatical representations of outdoor
areas). Do not use it for indoors or in an enclosed
area. Always ensure that adequate fresh air
ventilation is provided.
Do not use the heater for the heating of domestic
premises.
Do not use the heater in the basements or below
ground level.
Always maintain 120 cm (47") clearance from
combustible materials, or minimum 45 cm (18") top
and 60 cm (24") sides.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where gasoline or other
flammable liquids or vapours are stored.
To protect heater from strong wind, anchor the base securely to the ground with screws.
Gas Requirements
Use propane, butane or LGP only.
The heater is designed for use with 10kg cylinder. Maximum size of cylinder suitable for the
appliance is 30 cm x 59 cm (H). Inner dimension of stand with supporting bars is 325cm x 60
cm (H).
The appliance requires approved gas hose in 60 cm length and a regulator.
Regulator maximum inlet pressure must not exceed 690 kPa(100 PSI) .
Regulator outlet pressure to be 28 mbar(2.8 kPa or 11" W.C.) to 50 mbar depending on
countries.
The hose and regulator assembly must conform to local standard codes.