Fire-Lite H355 Installation And Maintenance Instructions Download Page 4

F300-25-00

4

I56-1972-00R

©2002 Fire•Lite  

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harm-
ful interference to radio or television reception, which can be determined by turning the equipment off and on,  the 
user is encouraged to try to correct the interference by one or more of the following measures:

– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.

Please refer to insert for the Limitations of Fire Alarm Systems

Summary of Contents for H355

Page 1: ... temperature alarm Model H355R is a rate of rise temperature sensor with 135 F fixed temperature alarm Model H355HT is a high temperature sensor with 190 F fixed temperature alarm Two LEDs on each sensor light to provide a local visible sensor indication Remote LED annunciator capability is avail able as an optional accessory Part No RA400Z Models H355 H355R and H355HT require compatible addressab...

Page 2: ...ch when activated prevents removal of the sensor without the use of a tool See the installation instruction manual for the sensor base for details in using this feature TESTING SENSITIVITY Before testing notify the proper authorities that the system is undergoing maintenance and will temporarily be out of service Disable the system to prevent unwanted alarms All sensors must be tested after instal...

Page 3: ...s described under MAINTENANCE and retested If the detectors still fail these tests they should be returned for repair Figure 3 Views showing position of test magnet F300 25 00 3 I56 1972 00R LED TEST MAGNET MARKER LED TEST MAGNET MARKER A78 1478 06 A78 1944 02 MAINTENANCE NOTE Before cleaning notify the proper authorities that the system is undergoing maintenance and therefore the system will temp...

Page 4: ...iate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harm ful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Reviews: