GD14 

 

Installation Guide 

 

 

Operating Instructions 

 

 

Warranty 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GD14 1000

Page 1: ...GD14 Installation Guide Operating Instructions Warranty...

Page 2: ...rly the steel surrounding glass panels to the face or the door become extremely hot during operation and can result in serious injury and burns if touched It is therefore recommended that a fireguard...

Page 3: ...o these minimum clearances is the base and the front surround panels of the appliance The base can safely sit directly upon combustible e g timber and non combustible e g concrete materials Check appr...

Page 4: ...st 2020 4 Burner Removal Process Burner removal Remove the 4 x screws The pilot end of the burner aligns with the seam in the outer brazier panel Remove the burner and place in a suitable location to...

Page 5: ...burner tube both LPG and NG Lower the burner into the Brazier Take care not to bend the gas supply pipe GD14 700 1000 Fit the 4 x screws The pilot side of the burner aligns with the seam in the outer...

Page 6: ...ctrical supply cable will need to be run into the weather housing must be a minimum of 1 0mm 4 core cable ensure 1000mm of cable is at the centre of the cavity as this is where it will connect to the...

Page 7: ...e specification for the correct clearance requirements Ensure the framing is capable of supporting a 250kg load In order to provide maximum positioning flexibility the base of the appliance has a flan...

Page 8: ...nection details using the 4 core cable that has been run at site connect the switch to the appliance IMPORTANT Before testing ensure the gas valve is turned OFF Test electrical functions by switching...

Page 9: ...Version August 2020 9...

Page 10: ...to main valve Leak test all joints Switch the appliance ON Test adjust high pressure first using the outer brass nut and then the low pressures against rating plate specifications In the unlikely even...

Page 11: ...er tubes Failure to place the medium correctly may result in the appliance performing inefficiently Open the firebed cardboard box and identify firebox mediums GD14 700 Forest Logs Two firebed mediums...

Page 12: ...Version August 2020 12 How to lay Forest Logs Firebed GD14 700 Lay logs and rocks first in these positions 1 Pilot side 2 Pilot side 3 Pilot side 4 Pilot side 5 Non Pilot side...

Page 13: ...burning under logs Missing flames along the middle of the logs Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Repeat th...

Page 14: ...Version August 2020 14 How to lay Forest Logs Firebed GD14 1000 Lay logs and rocks first in these positions 6 Pilot side 7 Pilot side 8 Pilot side 9 Pilot side 10 Non Pilot side...

Page 15: ...burning under logs Missing flames along the middle of the logs Both these issues can be resolved by switching the appliance OFF and slightly repositioning rocks and logs at the problem areas Repeat th...

Page 16: ...perate appliance Following the GD14 Operating Instructions on the next page show the owner how to switch the appliance ON and OFF and how to switch between HIGH and LOW settings If the owner is not av...

Page 17: ...3 Low or poor pilot flame 4 Signal from flame rectifier interrupted 5 Signal to sparker electrode interrupted 6 Incorrect sparker electrode gap 1 Check gas supply 2 Check power supply 3 Check flame s...

Page 18: ...d warping if a firebox outer skin or support frame defect occurs contact The Fire Dept and the defect will be repaired or replaced at our discretion with all costs covered The Fire Dept warrants the S...