background image

Summary of Contents for XL-3

Page 1: ..._ _ _ i XL 3 SECURITY SYSTEM OWNERS MANUAL FIRE BURGLARY INSTRUMENTS INC N9115 5 92 01992 FBX ...

Page 2: ...mount keypad with 12 LEDs for monitorfng ZQ status 1 I 7015 Keypad with a plastic case and with indicator lights to show the status of I each of the zones The zone indicator lights are located behind the plastic sliding door of the keypad left hand side NOTE This keypad displays zone status indication lights for 16 zones I 7005 Keypad with a plastic case and a two line LCD liquid crystal display w...

Page 3: ...ARM ONLY MAID CODE 16 DOOR STRIKE USER CODE 17 KEYPADTAMPER 18 QUICK ARMING 19 QUICK FORCED ARMING 20 SET TIME OF DAY 21 ZONE DIRECTORY 22 SET AUTO ARM TIME 23 CHIME MODE 24 READ CLOCK TIME 25 READ AUTO SET TIME 26 DOOR STRIKE COMMAND 27 INSTALLATION LAYOUT 28 SYSTEM TESTING 3 4 z 7 8 8 9 9 10 10 11 11 11 11 12 12 12 12 12 12 13 13 13 13 13 14 15 FCC STATEMENT 16 LIMITATIONSSTATEMENT 17 OWNERS INF...

Page 4: ...m is running on AC ON or backup battery OFF If the light is blinking slowly then the battery is low if it is blinking rapidly then there is a telephone line failure detected 4 READY Indicates whether the system is ready for arming ON Ready OFF Not Ready In addition the RDY light shows the arming status if the ARMED LED is ON as follows OFF Armed in Away mode Slow Blink Armed in STAY mode interior ...

Page 5: ...TANT Indicates system is ARMED with all delay zones instant 6 AC indicates system is running on AC ON or backup battery OFF 7 BAT Indicates low battery Slow pulse low battery OFF Normal 8 COM Indicates a communications failure with the Central station 9 NUMERICAL KEYPAD operates in a similar manner to a calculator or telephone with the digits 0 9 and l clearly marked 10 DISPLAY AREA This section o...

Page 6: ...will appear _ 1SYSTEM READY I If the system is ready ARMING can be performed as follows ARMING PROCEDURE 1 Enter your four digit user code into the keypad USER The ARMED indicator light wili now be lit and if you are leaving the home you may exit through a door designated by your installer as an exit entry zone for a fixed time period known as the exit delay The entry exit times for your system ar...

Page 7: ...eady by observing the zone indicator lights or the display section of the LCD keypad Fromthe zone numberyou can find out which area of protection is not ready For example assume the zone 1 is not ready Typically this might mean that a protected door or window is open l Once the problems with each zone have been resolved the READY light will appear and the system can be armed To ARM the system when...

Page 8: ...ill appear on the display The conditions thh 1 have occurred appear in the zone display section of the keypad LED based keypads will reflect the current system status through the indicator lights as follows ALARM Fastblinking BYPASS Slowblinkinglowintensity TROUBLE Slowpulse NOTREADY SolidON Burglary alarms will be indicated with a STEADY sound through the keypad while FIRE alarms will generate a ...

Page 9: ...ones Remember you must DISARM the system to when you want to leave the premise Note The STAYoption will automatically be reset after the system is disarmed 7 INSTANT The INSTANT mode arms the system and eliminates the entry time delay interval This mode could be used so that if anyone enters through an entry exit zone the alarm system will instantly activate The system must be ready to select the ...

Page 10: ...not ready or faulty from activating the security system BYPASS PROCEDURE BYPASS USER ZN Depress the BYPASS key followed by your user code and two digit zone number 01 12 to be bypassed Example BYPASS USER 02 bypasses zone 2 Ifthe zone has been bypassed already the sequencewill unbypass the zone except if the system is armed and the unbypassed zone is still not ready Unbypass returns the zone to pr...

Page 11: ...er2 four digits US number User number 01 30 USID New user ID 0000 9999 Note lfambushcode capability has been enabledby your installing company then user number30 will be used as the system ambush code If an armingonly code maid code has been defined by your installer then user number 29 can only arm the system If a single user door strike code has been created by your installer then user number 28...

Page 12: ...llows KFYS Panic l Fire 7 9 Aux 1 3 For example to initiate a keypad panic signal press the l and keys at the same time Consult with your alarm installer to determine the operation of these conditions within your system In UL installations the AUX alarm is silent The 4612SM keypad has keys for specially defined auxiliary functions Their functions are activated by simultaneously depressing two keys...

Page 13: ...four digits US number User number Ol 30 USID New user ID 0000 9999 Note lf ambush code capability has been enabledby your installingcompany then user number30 will be used as the system ambush code If an armingonly code maid code has been defined by your installer then user number 29 can only arm the system If a single user door strike code has been created by your installer then user number 28 is...

Page 14: ...ON KEYSTROKES Panic Fire 7 9 Aux 1 3 Forexample to initiate a keypad panic signal press the l and keys atthe same time Consult with your alarm installer to determine the operation of these conditions within your system In UL installations the AUX alarm is silent The 4612SM keypad has keys for specially defined auxiliary functions Their functions are activated by simultaneously depressing two keys ...

Page 15: ...d by the installer this command 2 arms the system wtthout entering a user code and bypasses any unready burglary zones Quick forced arm 2 20 SET TIME OF DAY 3 The system contains a real time clock for the auto arming and system test capability The time of day can be set through any keypad using the following command 3 USER HR MN Time entry is performed in 24 hour time military time For exampleto s...

Page 16: ...auto armingtime enter 5 USER HR MN Forexample than f 3 the auto arming time to 11 45 PM user code of 5678 enter 5 5878 23 45 NOTE All times are entered in 24 hour military time This feature is disabled in UL installations 23 CHIME MODE 6 The optional chime modecauses the keypadto beepfor one second everytime selected zones such as the entrance door are opened while the system is disarmed For examp...

Page 17: ...the installer this command 2 arms the system without entering a user code and bypasses any unready burglary zones Quick forced arm 2 20 SET TIME OF DAY 3 The system contains a real time clock for the auto arming and system test capability The time of day can be set through any keypad using the following command 3 USER HR MN Time entry is performed in 24 hour time military time For example to set t...

Page 18: ...to armingtime enter 5 USER HR MN For example chanrj the auto arming time to 11 45 PM user code of 5678 enter 5 5678 23 45 NOTE All times are entered in 24 hour military time l This feature is disabled in UL installations 23 CHIME MODE 6 The optional chime modecauses the keypad to beep for one second everytime selected zones such as the entrance door are opened while the system is disarmed For exam...

Page 19: ...ssure that everyone knows what to do 6 Establish a meeting place outside where your family is to report Once you have evacuated the house do not return to a burning house 7 Advise the local fire authority that you have installed a fire alarm system 8 When the fire alarm signals LEAVE IMMEDIATELY Do not stop for belongings 9 If a fire occurs Jest the door If hot use your alternate route If the door...

Page 20: ... to silence the system and return to normal status BATTERY TEST Inorder to test the backup battery the following procedureshould be performed l Remove the AC transformer from the AC outlet by removing the restraining screw which secures the transformer to the wall Note the screw is not present in models sold in Canada 2 Observe that the AC light goes off on the keypad 3 Activate your alarm system ...

Page 21: ...erent outlet so that it and the radio or television receiver are on different branch circuits ff necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful interference Handbook This booklet is available from the U S Government Printing Office...

Page 22: ...UnitedStates they may not activate or provide early warning for a variety of reasons in as many as 35 of all fires according to data published by the Federal Emergency Management Agency Some of the reasons smoke detectors used in conjunction I with this System may not work are as follows Smoke detectors may have been improperly installed and positioned Smoke detectors may not sense fires that star...

Page 23: ...ever loud may not warn hearing impaired people or waken deep sleepers l Telephonelines neededto transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of setvice Telephone lines are also subject to compromise by sophisticated intruders Even if the system respondsto the emergency asintended however occupants may have insufficient time to prot...

Page 24: ...RESS CITY STATE ZIP TELEPHONE NUMBER EMERGENCY NUMBERS CENTRAL STATION FIRE DEPARTMENT POLICE DEPARTMENT NEIGHBOR GAS ELECTRIC COMPANY DOCTOR HOSPITAL EMERGENCY SERVICE INFORMATION ALARM INSTALLING COMPANY c XL 3 USER S MANUAL Page 19 ...

Page 25: ...E CHIME MODE DISPLAY CLOCK TIME SEQUENCE USER1 USER USER STAY USER INSTANT STAY USER OR STAY INSTANT USER BYPASS USER Zn BYPASS Zn If zone is already bypassed USER CODE USER USER NUMBER USID CODE USER USER NUMBER l 79 13 1 2 3 USER HH MM 4 5 USER HH MM 6 7 DISPLAY AUTO ARM TIME 8 DOOR STRIKE 9 USER TRIGGER NUMBER l LCD KEYPADS ONLY NOTE The time needs to be set if all of the LEDS on the LED based ...

Page 26: ... INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN THE LOSS OR DAMAGE IS CAUSED BY ITS OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential da...