FLS M9.05

CONDUCTIVITY MONITOR &

TRANSMITTER

saFety instructions

pacKinG List

General Statements

• Do not install and service the product without following the Instruction 

Manual.

• This item is designed to be connected to other instruments which can be 

hazardous if used improperly. Read and follow all associated instrument 

manuals before using with it.

• Product installation and wiring connections should only be performed by 

qualifi ed staff.

• Do not modify product construction.

Installation and Commissioning Statements

 

• Remove power to the instrument before wiring input and output connections.

• Do not exceed maximum specifi cations using the instrument.

• To clean the unit, use only chemical compatible products.

Please verify that the product is complete and without any damage. 

The following items must be included:

• M9.05 conductivity Monitor & Transmitter

• Instruction Manual for M9.05 conductivity Monitor & Transmitter

Summary of Contents for FLS M9.05

Page 1: ...duct installation and wiring connections should only be performed by qualified staff Do not modify product construction Installation and Commissioning Statements Remove power to the instrument before wiring input and output connections Do not exceed maximum specifications using the instrument To clean the unit use only chemical compatible products Please verify that the product is complete and wit...

Page 2: ...te values of conductivity and temperature to external devices A proper combination of digital outputs allows customized setups for any process to be controlled F3 00 F3 20 F6 30 F3 10 F3 05 F6 60 F6 61 F111 M9 05 ULF F3 80 pH ORP200 pH ORP400 pH ORP600 C150 200 C100 C300 C6 30 M9 05 X X Technical Data General Associated sensors FLS conductivity sensors and FLS temperature sensors Materials case AB...

Page 3: ...steresis User selectable 2 x Relay output user selectable as ON OFF Proportional frequency Proportional Pulse Timed Pulse Off mechanical SPDT contact expected mechanical life min operations 107 expected electrical life min operations 105 N O N C switching capacity 5A 240VAC max pulse min 60t hysteresis User selectable Environmental Operating temperature 20 to 70 C 4 to 158 F Storage temperature 30...

Page 4: ...all installation The panel version is installed using the panel mounting kit M9 SN1 while the wall mounting version is got fixing the panel mounting version on the wall mounting kit F9 KWX The mounting kits can be ordered directly connected to the monitor or separately and then simply installed on it PANEL MOUNTING WALL MOUNTING ...

Page 5: ...ils M9 SN1 Wall installation Use the panel mounting kit M9 SN1 to fix the M9 05 on the dedicated frontal cutout of the wall mounting kit F9 KWX Tighten front screws of box and waterproof connectors of cables internally mount caps on screw sites to get a IP65 watertight installation ...

Page 6: ...upper part of the terminals for an easy cabling Insert wire tip or ferrule completely into the terminal and fix with the screw until finger tight Do not route the sensor DC power or 4 20mA cables in conduit containing AC power wiring Electrical noise may interfere with sensor signal Routing the sensor cable in grounded metal conduit can help prevent electrical noise and mechanical damage Wall Inst...

Page 7: ... 4 20 mA Input 2 PLC Terminals 4 20 mA Input 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP 1 21 22 23 24 Power Supply 12 24 VDC 12 24 VDC PLC 4 20 mA Input 2 4 20 mA Input 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP 1 21 22 23 24 Power Supply 12 24 VDC 12 24 VDC PLC 4 20 mA Input 2 4 20 mA Input 1 V 2 1 L L L L 21 22 23 24 r Supply 4 VDC 4 VDC PLC 0 mA ut 2 0 mA ut 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP 1 ...

Page 8: ...strument digital input with separate Power Supply Connection to a PLC Instrument digital input for Voltage Free Contacts REED N O COM 3 4 Power Supply 12 24 VDC 12 24 VDC PLC Instrument Digital INPUT Digital INPUT Imax 50mA lmax 50mA lmax 50mA PLC DIGITAL INPUT N DIGITAL INPUT 2 DIGITAL INPUT 1 REF PLC N O Imax 50 mA Imax COM 3 4 lmax 50mA lmax 50mA Pt100 Pt1000 two wires connection Pt100 Pt1000 n...

Page 9: ...ding to Relay setting If Imax 50 mA use external Relay Connection to an User NO 10 11 12 RELAY 2 NC COM Alarm AC or DC Power NO 10 11 12 RELAY 2 NC COM Alarm AC or DC Power N O 3 4 COM AC or DC Power User Imax 50mA N O 3 4 COM AC or DC Power User Imax 50mA lmax 50mA N O 3 4 COM AC or DC Power User Imax 50mA N O 3 4 COM AC or DC Power User Imax 50 lmax 50mA N O N O N C COM 4 3 COM External Relay V ...

Page 10: ...th priority The five push buttons of the keypad are used to navigate display levels and modify settings The function of each button may change according to display level please refer to following table View level menu directory conductivity and temperature item code software release conductivity or temperature analog output 1 conductivity or temperature analog output 2 conductivity direct access t...

Page 11: ...efault Data Probe Signal Hold Reed Statistic Output Statistic Settings Data Statistic Reset to modify an item to scroll right to return to Menu without saving to save new settings Conductivity Unit Temperature Unit Temperature Compensation Factor Cell Constant Temperature Compensation Mode Manual Temperature TDS Factor Reference Temperature 1 SSR 2 SSR 3 RELAY 4 RELAY Output Test 4 20mA1 4 20mA2 ...

Page 12: ... of failure a reference number correlated to the involved digital output is reported by the out put number PROCEDURE FOR OUTPUTS SETTING go to the Options menu enter into the Outputs activation sub menu enable output s go to the Outputs menu set the operating mode for each enabled output Monitor without digital output activated In case a digital output is enabled a icon will appear In case a digit...

Page 13: ... MODE icon reports PRP acid dosing TIMED MODE icon reports TMD alkaline dosing Hysteresis Setpoint Output relaxed Output energized Cond Time Set Point I His Set Point I Prop Band Relay Prop Cond Set Point I His Set Point I Cond Relay Timed Endpoint 100 pulses from 0 to max pulses min Starting point 0 pulses 5 10 Set Point I His Set Point I Prop Band Relay Prop Cond Set Point I His Cond Set Point I...

Page 14: ... S S R 2 mech relay accessories Spare parts Part No Name Description M9 KW1 Wall mounting kit 144x144mm plastic box for wall installation of all panel mount monitors M9 KW2 Wall mounting kit with power supply 144x144mm plastic box and 110 230VAC to 24 VDC power supply for wall installation of all panel mount monitors Part No Name Description M9 SN1 Fixing snails 2 fixing snails for panel installat...