39
SET PLUS 2.0 - SET 2.0
Annex 3:
SET 2.0 - 60/70/80/100/120/200 wiring diagram
TERMINAL
BOARD WIRING DIAGRAM
230 V
AC
line side
Probe side max. 12 V
Danger
W
arning
SPECIAL
CONTROLLER FUNCTIONS
TO ENABLE:
6.1.1
Type of pump = 0-10V
6.1.2 Pump = Profie 7 6.1.3 Output signal = Normal
CA
N
CA
NV
FS
2V
FS
1
S6
+
V2
V1
S5
S4
S3
S2
S1
-
R3
R3
IR
2R
1L
N
PE
LV
Flow meter --> LFWC VFS1 connector
Power supply 824080021 - FROR 3x1.5 wire L
-->
Phase
N
-->
Neutral
825010586 SET
E.B. 0-10V
Pump --> E.B. QF1 824080021 - FROR 3x1.5 wire Phase
-->
brown
Neutral
-->
blue
LFWC controller --> QF2 E.B. 824080094 - FROR 3x1 wire L
-->
206
N
-->
207
0-10V control --> LFWC 824080065 - bipolar shielded wire -
-->
GND
(brown)__I_
V1
-->
Sign. 0-10V (white) IN
IF module Ext. Min/Ext. Of
f
230V
AC 50-60Hz power lines
Use right side of terminal board for connection
!
Terminal:
Connection for
:
L
Mains phase conductor L
N
Mains neutral conductor N
R1
Relay 1
R2
Relay 2
R3
Relay 3 (normally closed)
R3I
Relay 3 (normally open)
The PE protective conductor shall be connected to the PE metal terminal board!
Low voltage
max. 12V
AC/DC
Use left side of terminal board for connection
!
Terminal:
Connection for
:
S1
Circulation (opt.)
S2
Cold water (opt. see below)
S3
Primary circuit (opt.)
S4
High storage (opt.)
S5
Medium storage (opt.)
V1
0-10V/PWM primary pump
signal
V2
0-10V/PWM signal (opt.)
S6
Primary circuit return (opt.)
-
Probe bridge
VFS1
Cold water inlet
VFS2
optional
The polarity of probes PT1000 can be selected freely
.
Relay connections change based on the additional functions selected. Connect grounding probe (1-6) with probe attached to terminal board (-). VFS probes shall be connected to the power outlet on the control panel. Probe 2 / Cold water: when not connected, no probe is set to a temperature of 10°C.