Fiori P44I Instructions And Advice For The Use, Installation And Maintenance Download Page 7

7

INSTALLATION

CAUTION:

The hob SHALL not be installed below or adjacent to curtains or the like
For other combustible materials the following clearances SHALL be maintained;
 

- 600 mm in a vertical distance and 200 mm in a horizontal distance

4) FIXING THE COOKTOP

The hot plate has a special seal which prevents liquid from getting into the cabinet. Strictly comply
with the following instructions in order to correctly apply this seal:

Detach the seals from their backing, checking that the transparent protection still adheres to the seal itself.
Overturn the hot plate and correctly position seal “E” (fig. 10) under the edge of the hot plate itself, so that 
the outer side of the seal perfectly matches the outer edge of the hot plate. The ends of the strips must fit 
together without overlapping.
Evenly and securely fix the seal to the hot plate, pressing into place with the fingers and remove the strip 
of protective paper from the seal and set the plate into the hole made in the cabinet.
The prospective walls cutout that exceed the working table in height must be at a minimum distance from 
the cutting as mentionned both in the columns and the scheme.
In order to avoid accidental touching of overheated bottom of the hob, during operation, it is necessary to 
put a wooden insert, fixed by screws, at a minimum distance of 50 mm from the top (see fig. 8).

5) LOCATION AND VENTILATION

Ventilation must be in accordance with AS5601/AG 601 – Gas Installations.
In general, the appliance should have adequate ventilation for complete combustion of gas, proper flueing 
and to maintain temperature of immediate surroundings within safe limits.

6) GAS CONNECTION
Before connecting the appliance, check that the values on the data label affixed to the underside 
of the cooktop correspond to those of the gas mains in the home.
A label on the appliance indicates the regulating conditions, type of gas and working pressure.

WARNING

A gas hob must only be connected by Licensed Authorised Person and in accordance with the 
Standard AG601/AS5601 - Gas installation
This Gas Hob is NOT recommended for Maritime use.

* This appliance is suitable for a flexible connection;
- Natural Gas Fittings;
Regulator supplied, isolating valve and union are to be fitted.

- L.P.G. Propane Fittings;

Test point adaptor, isolating valve and union are to be fitted


Fig.10

Fig.11

Summary of Contents for P44I

Page 1: ...struction manual as indicated and on the appliance itself Fiori shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance INSTRUCTIONS AND ADVICE FOR THE USE INSTALLATION AND MAINTENANCE OF BUILT IN GAS HOBS MODELS P44W P44I P44TCW P44TCI Fiori shall not be held responsible for any inaccuracies in this handbook due to printing or ...

Page 2: ...id Back Burner control nr 1 8 Wok Burner control nr 2 9 Rapid Burner control nr 3 10 Semirapid Front Burner control nr 5 DESCRIPTION OF THE HOT PLATES Appliance dimensions mm Width mm 600 Depth mm 510 Height mm 50 Attention this appliance has been manufactured for domestic use only P44W P44I P44TCW P44TCI 600 510 Gas Connection Electrical Supply Cord 107 600 510 Gas Connection Electrical Supply Co...

Page 3: ...nob to the reduced rate position small flame fig 1 Always place a lid on the pans Burners Power ratings Pan Ø in cm Natural Propane Wok 14 5 MJ 14 5 MJ 22 24 Rapid 12 0 MJ 12 0 MJ 20 22 Semirapid 7 3 MJ 6 9 MJ 16 18 Auxiliary 4 2 MJ 3 8 MJ 10 14 WARNINGS Matches can be used to ignite the burners in a blackout Never leave the appliance unattended when the burners are being used Make sure there are ...

Page 4: ...idered to be abnormal operation and may require servicing Yellow tipping of the hob burner flame Sooting up of cooking utensils Burners not igniting properly Burners failing to remain alight Burners extinguished by cupboard doors Gas valves which are difficult to turn In case the appliance fails to operate correctly contact FIORI for your closest authorised service provider in your area REGULATION...

Page 5: ...coffee milk salted water lemon or tomato juice or other corrasive material to remain on the surface of the Hob or components for any extended period of time Ensure that the Ignition plug is clean and free of foreign matter WARNINGS Ensure the following is carried out before re assembling the components Check that the burner head slots are not clogged with foreign matter carbon etc Ensure that the ...

Page 6: ... within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the cooktop will be installed are indicated in fig 8 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 9 The hob SHALL NOT be installed below or adjacent to curtains or the like For ...

Page 7: ... be at a minimum distance from the cutting as mentionned both in the columns and the scheme In order to avoid accidental touching of overheated bottom of the hob during operation it is necessary to put a wooden insert fixed by screws at a minimum distance of 50 mm from the top see fig 8 5 LOCATION AND VENTILATION Ventilation must be in accordance with AS5601 AG 601 Gas Installations In general the...

Page 8: ...ssure check and adjust the gas burners if necessary see page 9 for ADJUSTMENTS 7 ELECTRICAL CONNECTIONS The data label can be found on the underside of the cooktop Check that the voltage rating of the appliance corresponds to the supply voltage The Hob may be connected to a 3 core supply flexible cord and a 10 ampere plug The electrical connections of the appliance must be carried out by a qualifi...

Page 9: ...ta Plate When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 8 GAS TAPS Our gas taps are suitable for all gases they are a male conical type Reduced rate adjustment Switch on the burner and turn the relevant knob to t...

Page 10: ...gulation on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of the injectors and the working ...

Page 11: ...pillage preventing it from sparking SPARK BUT NO GAS Make sure that gas is turned on Check that the burner holes are not blocked SMELL OF GAS Check to see if any gas tap has been inadvertently left on If they are all off then immediately switch off gas at mains and call Customer Call Centre DO NOT under any circumstances press igniter or search for leak with naked flame STILL NOT WORKING Call Cust...

Page 12: ...purposes and where normal vehicular access is provided 2 The warranty does not apply for the following a Light globes b To paint finishes and glass c If defect is caused by misuse wear and tear dirt fire accidental damage or faulty electrical conection d If the product has been repaired or serviced by an unauthorised person e If installed contrary to Fiori Holdings Pty Ltd instructions 3 For warra...

Page 13: ...ces Waterford Park Dalgety 2628 02 6456 5234 04 2711 0247 NSW Deniliquin I D Appliance Service 254 Henry St Deniliquin 2710 03 5881 6900 03 5881 5186 NSW Forster Germon Electrics Bay 5 lot 7 Kularoo Drive Forster 2428 02 6555 6694 02 6554 8538 NSW Forster Taree G r e a t L a k e s Appliances 1 6 C o m m e r c e Court Forster 2428 02 6555 6550 02 6554 9766 NSW Gloucester B u c k e t s W a y Electri...

Page 14: ... Services P L 67 Princes Hwy Fairy Meadow 2519 02 4285 9873 02 4284 9873 NSW Yass Mark Garland Ap pliance Service 7 Hovell St Yass 2582 02 622 628 73 02 6226 2873 NT Darwin Mobile Electrics 11 Goyder Rd Darwin 0801 08 8941 1217 08 8936 1888 QLD Ayr Coral Coast Electrical 133a Edward St Ayr 4807 07 4783 4835 07 4783 4711 QLD Brisbane Endeavour Refrig eration 167 Robertson St Fortitude Valley 4006 0...

Page 15: ...t 3218 03 5223 2856 03 5221 6588 VIC Horsham J D J M English 56 Mc Pherson St Horsham 3400 03 5382 3924 03 5382 2568 Vic Melbourne Metro East side Northern Home Appliances 324 Waverley Rd Malvern East 3145 03 9572 0401 03 9572 0400 VIC Melbourne Nth West side Stindl Home Appli ance Service 71A Hotham Rd Niddrie 3042 03 9379 3627 03 9374 1129 Vic Mildura Jack Abel 2 4 Tenth St Mildura 3500 03 5023 ...

Page 16: ...for any possible imprecision in this booklet due to misprints or clerical errors It reserves the right to make all the changes that it will consider necessary in its own products without affecting the essential characteristics of functionality and safety ...