EN
12
Tighten the wing nut.
6.7 Spark plug
Detach the spark plug connection.
Unscrew and clean the spark plug.
Screw the clean or a new spark plug.
Apply the spark plug connection.
It is possible to completely empty the hydraulic
circuit through two plugs on the bottom of the
tank.
6.9 Transmission Belts
The machine has three poly-V transmission belts.
One for the intake fan, one for the pump unit and
the third for the dynamo-starter motor and battery
charger.
Periodically (approximately 300 hours of operation)
check belt tension and adjust if necessary.
The belt tensioners A and B act respectively on
the belts of the pump unit and engine dynamo.
6.8 Hydraulic Oil
Extract the waste container.
This way the hydraulic oil level and filler cap
remain visible.
In order to adjust the tension of the belts, you must
first slightly loosen the screws 1 and 2 and then
loosen the lock nut of the belt tensioning
mechanism.
Top up if the level is not correct.
See the technical specifications for the type of
hydraulic oil.
Every 500 hours of operation, replace the filter
cartridge in the hydraulic circuit.
HAZARD
Risk of injury and damage.
A belt tension meter should be used.
Incorrect belt tension can lead to rapid
wear or sudden breakage of the
component, with possible damage to
the machine and dangerous projection
of parts of the belt.
HAZARD