Installation and User Manual

Sydney

Summary of Contents for Sydney ICOOL

Page 1: ...Installation and User Manual Sydney ...

Page 2: ...RESH AIR SYSTEM OPTIONAL FRONT PANEL FUNCTION 2 4 FASTENING THE BRACKET 2 5 FITTING THE GRATINGS 2 6 FIXING PLASTIC SHEET AND INSULATION 2 7 CONNECTING DRAINAGE PIPE 2 8 FITTING THE AIR CONDITIONER ON BRACKET 7 8 9 10 11 19 3 14 3 15 3 13 FRESH AIR FUNCTION OPTIONAL ...

Page 3: ...om a power source of the same voltage frequency and rating as indicated on the product identification plate 1 1 INTRODUCTION Please note Don t dispose of any packaging until the installation of the air conditioner is completed After having removed the packing check that all the content is intact and complete See list of accessories In the event of missing parts contact your retailer This air condi...

Page 4: ...within reach of children since they are hiding of danger This product has been manufactured to comply with 2006 95 EC and with amendments 92 31 EEC and 93 68 EEC DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary Any batteries used in the remote control contain materials which are hazardous to the environment They...

Page 5: ...nser inlet fan Fron panel Air inlet area P2 The display will show both setting temperature and ambient temperature After adjusting the setting temperature the setting temperature will flash 15 times on the display then the display will show the ambient temperature for 70 seconds After that the display will be off until next adjustment Fuse T6 3A ...

Page 6: ... their leaves slats or panelling drain pipes overflows and gratings etc Any obstruction could interfere with the correct performances of the air conditioner The wall on which the air conditioner is installed must be sturdy and able to withstand the weight fo the air conditioner The air conditioner must be fitted leaving room all around as illustrated in the paper template Fasten the template to th...

Page 7: ...IO Cut back insulating material in this position to connect the machine without power plug or for MOD BUS connection Optional Tagliare l isolante posteriore della macchina in questa posizione per allacciare la macchina alla rete elettrica senza l utilizzo della spina shuko e per la connessione alla rete MOD BUS optional ...

Page 8: ...K for hot country and normal cold temperature outside DRAINAGE HOLE P8 WALL BRACKET HOLES P9 P6 7 8 9 Please note If you are drilling the hole above ground floor level please ensure that an area has been secured and while the holes are drilled the outside area is supervised until drilling has been completed INTAKE AND OUTLET HOLES P6 This operation should be carried out using the proper tools diam...

Page 9: ...chors into the holes for the unit and tighten them inside the wall The anchor bolts provided require 10mm holes the wall should be inspected to determine if provided bolts are useful or if it is necessary to use a different anchorage The manufacture is not liable in case of underestimation of the structural consistency of the anchorage made at the time of installation 2 5 Put the silicon gel aroun...

Page 10: ...es The sheets must be 107mm shorter than the thickness of the wall See P18 Use an ordinary cutter for the operation See P19 The black silicon gel is just for reference we could use white or transparent color gel to fix the outdoor grille See P17 P15 P16 P18 P19 P17 iCOOL unit Wall thickness T Fan thickness External grating thickness 77mm 30mm 5 0 0 m m 628mm T PLASTIC SHEET WITH INSULATION 2 6 FIX...

Page 11: ...e machine is installed in normal climate or hot area we can connect the drainage pipe to outside with a proper place See P23 Outdoor Indoor Drainage pipe P24 2 When the machine is installed in very cold area the water in drainage pipe is frozen easily in winter we could connect the drainage pipe inside the wall and connect with a proper place See P24 Outdoor Indoor Drainage pipe Roll the sheet and...

Page 12: ...l and that any necessary preparations for electric connection and condensate drainage have been made fasten the air conditioner to its supporting anchors See P25 Lift it up by holding the sides at the bottom slightly insert the outside fan rings into the two big holes on the wall See P26 The air conditioner can now be pushed firmly against the wall then lift the unit and make sure the anchors and ...

Page 13: ...e out the cable clip by plier from the side plate and remove the power cable from unit See P32 C Connect the wires passed through the hole of back plate Block window cap and fix rating label again Block the hole of power cable with a rubber cap supplied with the air conditioner See P32 D P31 P32 P33 A B A B C D Screw N N CO CO Screws 2 10 FRESH AIR SYSTEM OPTIONAL There is fresh air system in the ...

Page 14: ......

Page 15: ...3 3 HEATING MODE 3 4 COOLING MODE ...

Page 16: ...peed is middle speed is high speed flashing is auto speed Fan auto fan the speed is choosen by the difference of room temperature and setting temperature Room temperature setting temperature 5 high speed Room temperature setting temperature 3 middle speed Room temperature setting temperature 1 low speed Press the ON OFF button switch off the air conditioner Next time when this button is pressed th...

Page 17: ...3 7 SLEEP MODE 3 8 AUTO MODE ...

Page 18: ...3 9 TIMER OFF FUNCTION 3 10 TIMER ON FUNCTION 16 ...

Page 19: ...ery AAA 2pcs the positive must be same with the mark on the plastic surface Reinstall the cover of battery Inspection If press ON OFF button no icons are displayed please install the battery again Open the cover of battery hold the hook and lightly pull up Open position Close position Clean position Fresh air system Fresh air filter should be cleaned regularly to keep the fresh air flow smooth Tak...

Page 20: ...ioner from the electrical supply Wipe external surfaces clean with a damp cloth only Do not use an abrasive cloth or solvents as this may damage the surfaces Do not use excessively wet cloths or sponges as water stagnation could damage the air conditioner and compromise safety ACTIVE CARBON FILTER OPTIONAL P40 The unit maybe includes active carbon filter which not only has the function of eliminat...

Page 21: ...s Wrong insertion of the batteries inside the remote control Protection of the conditioner Wait for 3 min and the air conditioner will start to work again If the supply cord damaged it must be replaced by manufacturer or its service agent or a similarly qualified person in order to avoid a hazard The remote control does not work The air conditioner does not work for 3 min when switched on The max ...

Page 22: ...20 ...

Page 23: ...WWW FINTEKSRL COM via Tonso di Gualtiero 46 47896 Faetano RSM Tel 378 0549 901 950 Cell 39 393 1808 890 fintek fintek it www finteksrl com ...