Fintek OSLO 3.0 Installation And User Manual Download Page 18

3.USE AND  MAINTENANCE

ENGLISH 

3. 12  On  board  control  function only  for OSLO 4.0

© 

® 

® 

® 

(D  RUNNING  LED :Signal  the  working  state  of  compressor 

@  ON/OFF BUTTON : turn on or turn off the air conditioner 

@  MODE BUTTON: Set up the air conditioner operating mode 

©  COOLING  LED :Signal  the  cooling  state 

@  HEATING  LED: Signal  the  heating  state 

®  ELECTRICAL  HEAT  BUTTON: Turn  on  or  turn  off  the electrical heat. 

0  ELECTRICAL  HEAT  LED: Signal  the  electrical  heat  state. 

®  DOWN BUTTON : Decrease the temperature and time 

®  UP BUTTON: lncrease the temperature and time 

@)  FAN SPEED BUTTON: Set up the fan speed 

@  HIGH  SPEED  LED: Signal  the  high  speed  working  state 

@  MIDDLE  SPEED  LED :Signal  the  middle  speed  working  state 

@  LOW  SPEED  LED: Signal  the  low  speed  working  state 

@  AUTO  FAN  LED:  Signal  the  automatic  fan  state 

lf  you  select  the  AUTO  speed, the  fan  speed  is  according  with  the  room 

temperature  and  setting  temperature. 

Room  temperature-setting  temperature>5'C, high  speed. 

Room  temperature-setting  temperature>3'C,middle  speed. 

Room  temperature-setting  temperature>1 'C,low  speed. 

@  Temperature  display  window 

The  display  will  show  both  setting  temperature  and  ambient  temperature. 

After  adjusting  the  setting  temperature,  the  setting  temperature  will  flash 

15  minutes  on  the  display, then  the  display  will  show  the  ambient 

temperature  for  70  seconds.  After  that,  the  display  will  be  off  until  next 

adjustment. 

Summary of Contents for OSLO 3.0

Page 1: ...Installation and User Manual OSLO 3 0 4 0 ...

Page 2: ......

Page 3: ......

Page 4: ...S P0 1 FASTENING BRACKET 2 REMOTE CONTROL 3 REMOTE CONTROL HOLDER 4 DRAINAGE PIPE 5 EXTERNAL GRATING 6 PLASTIC SHEET AIR PIPE 7 KIT OF SCREWS 8 GRATING FIXING CORD 9 INSTRUCTION MANUAL 10 PAPER TEMPLATE FOR WALL DRILLING See page 11 160mm RING 12 150mm RING ...

Page 5: ...W P1 3480 11900 4162 14200 1287 1214 450 5 6 5 3 50 ...

Page 6: ...2m P3 2m Outdoor Indoor P4 spirit level ...

Page 7: ......

Page 8: ...ft terminal Hard terminal A A B B System A is more common use and the discharge pipe go outside where there is no problem to connect or to discharge it this solution is OK for hot country and normal cold temperature out side ...

Page 9: ...the air conditioner need to be fitted through them Measure the depth of the wall and cut supplied plastic sheet Roll the sheet and insert it into the hole paying attention to the joint line which must be always upper position Remember that the sheet must have the same inclination of the holes min 3 Insert the rings into the holes Please centre the pipes into the holes in the wall and insulate and ...

Page 10: ...P7 P8 P10 P9 ...

Page 11: ...LIFT IT UP HERE P11 P12 LIFT IT UP HERE Water P14 Water cap ...

Page 12: ......

Page 13: ......

Page 14: ...peed is low speed is middle speed is high speed flashing is auto speed Fan auto fan the speed is choosen by the difference of room temperature and setting temperature Room temperature setting temperature 5 high speed Room temperature setting temperature 3 middle speed Room temperature setting temperature 1 low speed Press the ON OFF button switch off the air conditioner Next time when this button ...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...LED Signal the high speed working state MIDDLE SPEED LED Signal the middle speed working state LOW SPEED LED Signal the low speed working state AUTO FAN LED Signal the automatic fan state lf you select the AUTO speed the fan speed is according with the room temperature and setting temperature Room temperature setting temperature 5 C high speed Room temperature setting temperature 3 C middle speed ...

Page 19: ...Close position ...

Page 20: ...LIFT IT UP HERE LIFT IT UP HERE P15 P16 P17 P19 P18 ...

Page 21: ...5 The temperature is not properly set Check it ...

Page 22: ......

Page 23: ...WWW FINTEKSRL COM via Tonso di Gualtiero 46 47896 Faetano RSM Tel 378 0549 901 950 Cell 39 393 1808 890 fintek fintek it www finteksrl com ...