2
MODEL
NO.
KW
MAX
Volts/
Phase/
Amps
Wire
Gauge
CU FT
RANGE
MAX DIM
L x W x H
(w/drain)
NET
WEIGHT
RV9
8.5
240/1/38
8
50-375
15”x5”x12”
24 lbs
RV13
13
240/1/55
6
50-600
15”x8”x12”
30 lbs
RV15
15
240/1/63
4
50-700
15”x8”x12”
30 lbs
RV18
18
240/1/75
3
50-800
15”x8”x12”
30 lbs
RS50
3.0
240/1/13
12
50-90
23”x7”x10”
25 lbs
RS100
4.5
240/1/19
12
90-150
23”x7”x10”
25 lbs
RS150
6.5
240/1/27
10
150-250
23”x7”x10”
25 lbs
RS250
8.5
240/1/36
8
250-375
23”x7”x10”
25 lbs
CS11
11
240/1/46
8
300-450
25”x9”x10”
30 lbs
CS12
12
240/1/50
6
400-550
25”x9”x10”
30 lbs
CS13
13
240/1/55
6
450-600
25”x9”x10”
30 lbs
CS15
15
240/1/63
4
500-700
25”x9”x10”
30 lbs
CS18
18
240/1/75
3
600-800
25”x9”x10”
30 lbs
CS24
24
240/1/100
1/03
up to 1200
25”x9”x18”
60 lbs
CS30
30
240/1/125
2/02
up to 1500
25”x9”x18”
60 lbs
CALCULATE THE STEAM ROOM'S VOLUME
(V)
in cubic feet by multiplying its length x width x height
(in feet).
Based on the construction design, determine one of
the highest applicable factors from the following and
multiply it by V.
1. If Ceramic Tiles, Glass Tile, or Block is used,
multiply V by 1.3.
2. If there is an external wall, or your steam room is in
the basement, multiply V by 1.6.
3. If Natural Stone, Marble, Slate, or Granite is used,
multiply V by 2.0.
SPECIFICATION SHEET