5.4.5  Menuselectie-INDIVIDUAL

zie 2) invoeren van de trajecten

2)  Invoeren van de trajecten/weerstandsniveaus

LEVEL 1-16

3)  Invoeren van de standaardinstelling

OFF, 10:00-99:00 min

OFF, 120-199 

slagen/minuut

Traject 1

Traject 2

LEVEL 1-16

Langer dan 2s ingedrukt 

houden.

Eerder ingevoerde gegevens beginnen terug te 

tellen, verder worden alle waarden naar boven 

geteld. Wanneer de doelwaarde is bereikt, klinkt 

een geluidssignaal en stopt de computer met de 

training.

Eerder ingevoerde gegevens beginnen terug te tellen, verder worden 

alle waarden naar boven geteld. Wanneer de doelwaarde is bereikt, 

klinkt een geluidssignaal en stopt de computer met de training.

Summary of Contents for TIVON 3271

Page 1: ......

Page 2: ...5 Menuselectie INDIVIDUAL 5 5 Foutdiagnose en foutopsporing 1 Safety instructions 03 2 General 04 2 1 Packaging 04 2 2 Disposal 04 3 Assembly 05 3 1 Assembly Steps 05 4 Care and Maintenance 11 11 11...

Page 3: ...ainingsdauer 8 Explosionszeichnung 9 Teileliste 10 Garantie 11 Service Hotline Ersatzteilbestellformular 6 Technical details 32 6 1 Adapter 32 6 2 Conformity according to the 7 Training manual 33 7 1...

Page 4: ...ich nicht Dritte in der N he des Ger tes befinden da weitere Personen durch die beweg lichen Teile verletzt werden k nnten 16 Das Trainingsger t darf nicht in feuchten R umen Bad oder auf dem Balkon a...

Page 5: ...toffe sind gem ihrer Kennzeichnung wiederver wertbar Mit der Wiederverwendung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten lei sten Sie einen wichtigen Beitrag zum Schu...

Page 6: ...Achten Sie darauf dass Sie w hrend des Zusammenbaus in jede Richtung hin gen gend Bewegungsfreiraum mind 1 5 m haben In order to make assembly of the item as easy as possible for you we have preassemb...

Page 7: ...06 Schritt Step 2...

Page 8: ...07 Schritt Step 3...

Page 9: ...08 Schritt Step 4...

Page 10: ...09 Schritt Step 5...

Page 11: ...10 Schritt Step 6...

Page 12: ...Care When cleaning use only a moist cloth and avoid harsh cleaning agents Ensure that no moisture penetrates into the computer Components that come into contact with perspiration need cleaning only wi...

Page 13: ...pulswaarde Waardebereik van 40 199 slagen per minuut Hier ziet u ook de berekende of voorgeprogrammeerde pulswaarde WAARSCHUWING Systemen voor hartfrequentiebewaking kunnen onnauwkeurig zijn Overmati...

Page 14: ...ets om de computer vanuit de sluimermodus te activeren Het trappen werkt niet in deze modus C Standaardinstelling Standaardinstelling Wanneer de standaardinstelling is bereikt klinkt een geluidssignaa...

Page 15: ...training door te beginnen met trappen Alle gegevens beginnen omhoog te tellen Bent u geregistreerd als gebruiker U0 dan worden de trainingsgegevens niet opgeslagen 1 USER selectie 3s indrukken zie 2...

Page 16: ...A B 15 a Leeftijd 20 90 jaar U gaat naar de menuselectie zie 5 4 2 2 Invoer van de persoonlijke gegevens kort indrukken...

Page 17: ...naar boven geteld Wanneer de doelwaarde is bereikt klinkt een geluidssignaal en stopt de computer met de training zie 2 invoeren van de standaardinstelling 2 Invoeren van de standaardinstelling U trai...

Page 18: ...s zie 2 selectie van de max pulsgrens Eerder ingevoerde gegevens beginnen terug te tellen verder worden alle waarden naar boven geteld Wanneer de doelwaarde is bereikt klinkt een geluidssignaal en sto...

Page 19: ...an de standaardinstelling voor 65 75 en 90 3B Invoeren van de standaardinstelling voor IND OFF 10 00 99 00 min OFF 1 999 km OFF 1 9990 Kcal OFF 10 00 99 00 min OFF 1 999 km OFF 10 9990 Kcal OFF 120 19...

Page 20: ...voerde waarden beginnen terug te tellen verder worden alle waarden naar boven geteld Wanneer de doelwaarde is bereikt klinkt een geluidssignaal en stopt de computer met de training U volgt het reeds i...

Page 21: ...EVEL 1 16 Langer dan 2s ingedrukt houden Eerder ingevoerde gegevens beginnen terug te tellen verder worden alle waarden naar boven geteld Wanneer de doelwaarde is bereikt klinkt een geluidssignaal en...

Page 22: ...he user selection MODE By pressing this key a function can be confirmed RECOVERY Recovery pulse measurement with assignment of a fitness score 1 6 Program selection or increase decrease of values A lo...

Page 23: ...actual heartrate range from 70 199bpm WARNING Systems with heartrate control can be incorrect To much exercise could injure your body or can cause dead If you feel light theaded or weak stop your exer...

Page 24: ...to pedal the set values will be confirmed and you start your exercise A Pedalling C Setting values Target values After achieving the target values there will be a beep and the computer will stop coun...

Page 25: ...the center of the digital display Start your exercise by pedalling You have activated the last used all values start counting up After you have finished your exercise the reached values will not be sa...

Page 26: ...a Age 20 90 years 25 2 Setting of personal datas...

Page 27: ...d If you didn t set any values all data will start counting up check 2 Setting of values 2 Setting of values Starting your exercise the already set data will start counting backwards If the set data r...

Page 28: ...of the max heartrate 1 HRC Selection Starting your exercise the already set data will start counting backwards If the set data reach 0 the computer will stop and a beep will be heard If you didn t set...

Page 29: ...e the already set data will start counting backwards If the set data reach 0 the computer will stop and a beep will be heard If you didn t set any values all data will start counting up Starting your...

Page 30: ...s If the set data reach 0 the computer will stop and a beep will be heard If you didn t set any values all data will start counting up Starting your exercise the already set data will start counting b...

Page 31: ...Starting your exercise the already set data will start counting backwards If the set data reach 0 the computer will stop and a beep will be heard If you didn t set any values all data will start coun...

Page 32: ...tween 5 0 5 5 kHz Moisten the electrodes and check for correct positioning Fout Geen weergave of de computer werkt niet Oorzaak Geen stroomvoorziening Fout Pulsweergave niet correct Oorzaak Geen ontva...

Page 33: ...en Netztrennung ist der Netzstecker aus der Steckdose zu ziehen Das Ger t deshalb nur an leicht zug ngliche Steckdosen anschlie en 6 1 Power Supply included in the scope of delivery Connect the cable...

Page 34: ...ter bei gleichem Puls eine h here Leistung vollbringen was eine Verbesserung der Form bedeutet Wenn Sie mit pulsgesteuertem Training bereits Erfahrung haben k nnen Sie Ihre gew nschte Pulszone Ihrem s...

Page 35: ...ungsf higkeit sollte im darauffolgenden Training immer eine regenerative Trainingseinheit im unteren Pulsbereich folgen bis 75 des Maximalpulses Note Because there are persons who have high and low pu...

Page 36: ...rd dar ber hinaus auch Fett verbrannt Nach 30 40 Minuten wird der Fettstoffwechsel aktiviert danach ist das K rperfett der haupts chliche Energielieferant When condition has improved higher intensity...

Page 37: ...arget Pulse Diagram Herzfrequenz Alter Heart Rate Age Herzfrequenz Herzschlag Min Heart Rate beats min Alter Age 220 Age Max heartrate 90 Max heartrate 70 Suggested lower limit Max heartrate 85 Sugges...

Page 38: ...8 Explosionszeichnung Explosiondrawing 37...

Page 39: ...38...

Page 40: ...llbearing 6003Z 4 34 Sechskantschraube Hex head bolt M8x20 4 35 Pedalarmabdeckung oben links vorne Top left front pedalarm cover 1 36 Pedalarmabdeckung oben links hinten Top left rear pedalarm cover 1...

Page 41: ...exhead screw M8x55 1 92 Magnetleiste Magnetic board 1 93 Sechskantschraube Hexhead screw M6x65 1 94 Unterlegscheibe Washer 6x 18x2 1 95 Mutter selbstsichernd Safety nut M6 1 96 Feder Spring 1 97 Motor...

Page 42: ...n unsere Ger te mit Erg nzungs oder Zubeh rteilen versehen werden die nicht auf unsere Ger te abgestimmt sind ferner wenn das Ger t durch den Einfluss h herer Gewalt oder durch Umwelteinfl sse besch d...

Page 43: ...on Liebig Str 21 89231 Neu Ulm Ort Datum Ersatzteilbestellung Bitte in Druckbuchstaben ausf llen Kaufdatum Gekauft bei Firma Garantieanspr che nur in Verbindung mit einer Kopie des Kaufbeleges Bitte l...

Reviews: