background image

02-4211-200  05/09/01                                                                                                                                                                                                                                            7014228      314 SKMB 27 B

    "Mini Finn" Heater Installation & Operation Instructions

WARNING

     SECTION 1: GENERAL INFORMATION

These heaters are UL approved for permanent installations and 
electrical connections.  Built with splash proof construction, the 
conducting parts are protected against water.  All wiring must be 
performed in accordance with local codes.  See Diagram 3 for wire and 
room size requirements.

These heaters are wall mounted, 15"W x 7"D x 17"H, with built in 
controls.

"MINI FINN" SERIES SAUNA HEATERS

MODELS FU21 & FU30 (With built-in control)

Read all instructions carefully before installation. Please 
leave all instructions and warranty with the owner. 

WARNING
Prolonged exposure to elevated temperatures is capable of inducing 
hyperthermia. Hyperthermia occurs when the internal temperature of 
the body reaches several degrees above the normal body temperature 
of 98.6°F. The symptoms of hyperthermia include an increase in the 
normal temperature of the body, dizziness, lethargy, drowsiness, and 
fainting. The effects of the hyperthermia include failure to perceive 
heat, failure to recognize the need to exit the room, unawareness of 
impending hazard, fetal damage in pregnant women, physical inability 
to exit the room and unconsciousness.

WARNING
The use of alcohol, drugs, or medication is capable of greatly 
increasing the risk of fatal hyperthermia.

Do not take a sauna if using 

alcohol, drugs or 

medications.

Pregnant women or persons 

with poor health should 

consult their physician 

before using any sauna.

Caution fire hazard: Do not 

use the sauna room for 
drying clothes, bathing 

suits, etc. Do not hang 

towels above heater or place 

any object, other than the 

rocks supplied, on the 

heater.  If any darkening of 

the wall around the heater 

is noticed discontinue 

sauna use immediately.

Inspect sauna regularly for 

required maintenance to 

heater, control and 

benches. Replace wood 

surfaces which show any 

signs of deterioration.

The heater gets extremely 

hot during operation and 

should not be touched or 

burns may result.

Minors should be 

adequately supervised 

whenever near a hot or 

warming sauna.

Summary of Contents for FU21

Page 1: ...al temperature of the body dizziness lethargy drowsiness and fainting The effects of the hyperthermia include failure to perceive heat failure to recognize the need to exit the room unawareness of imp...

Page 2: ...2 DIAGRAM 3 MIN DISTANCE FOR THE MOUNTING BRACKETAND TO COMBUSTIBLE MATERIAL B Page 2 3 min A DISTANCE B DISTANCE C DISTANCE 21T 3 1 1 4 1 1 4 30T 3 1 1 4 2 1 2 HEATER MINIMUM Floor Area Ceiling Heigh...

Page 3: ...ctrical Code and local regulations Remove the heater s electrical box cover and connect the feed wires to the terminal block To determine the correct wire size refer to Diagram 3 Use copper supply wir...

Page 4: ...7 8 9 ONE HOUR OPERATING ZONE FOR 9 HOUR DELAY TIMER This area from OFF to ON is the operating zone This is the only time the heater is on DELAY ZONE This area from 9 to ON is the delay zone meaning...

Page 5: ...er which means you can set the heater to begin heating after a delay of up to 9 hours If you set the timer dial in the 1 to 9 zone the heater will automatically turn on after the selected delay time h...

Page 6: ...3 4 5 6 120V AC 2 2 x 1500W 120V 1 1 x 2100W 120V 1 x 1700W 120V a1 a1 b0 b0 a b a b M V S U R 2100W or 3000W Timer 1h 9h preset N L Gr 1 2 3 4 5 6 240V AC 3000W L1 L2 Gr 4 7K min 3 5W 1 2 3 4 5 6 L1...

Page 7: ...at the cycle 2 or 3 times end with a brisk shower rinse in cool water Dress when completely dry and perspiration has stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on...

Page 8: ...Finn Heater Installation Operation Instructions DIAGRAM 7 DIAGRAM 8 TYPICAL PRE CUT WALL CONSTRUCTION 2x4 framing 1 2 wallboard fiberglass insulation 1 2 wallboard T G soft wood foil vapor barrier Loc...

Page 9: ...es spring or gravity loaded closures The door must always open outwards No shower can be installed in a sauna room No electrical receptacle shall be installed inside the sauna room The enclosed WARNIN...

Page 10: ...ts open when the sauna is not in use Saunas that are in daily use should be washed down at least once a week to keep them clean and the air fresh Duckboard should be removed from the sauna the sauna f...

Reviews: