25
CLEANING AND MAINTENANCE (CONTINUED)
SEASONAL AND WINTER STORAGE MAINTENANCE
1. Drain slurry tank of all water, prior to storage, and remove all drain plugs.
2. Park unit in suitable location and chock wheels to prevent inadvertent movement.
3. If possible, cover machine with tarp or park inside of an enclosure.
4. Store
HydroSeeder
®
with all slurry valve handles in the open position. To prevent damage
from freezing, it is advisable to remove all slurry valves and store in a heated area.
5. Pour 1 qt (0.95 L) of mineral oil or environmentally safe lubricant into pump housing and
spin pump by hand to prevent rust in pump. Remove drain plug.
6. Chip and steel-brush any interior rust spots in the slurry tank and touchup with paint. See
numbers 2 and 3 in IV. Maintenance of the HYDROSEEDER
®
Safety Summary Section.
7. Lubricate all fittings.
8. Change hydraulic oil and filter. (400 hours)
9. Disconnect battery cables. In cold weather, remove battery and store it in a safe, warm
place.
10. Add fuel stabilizer to fuel tank.
NOTE:
Make sure to lubricate equipment after it has been removed from storage
and before it is put back into operation. This will ensure that everything
has a fresh coating of grease.
HYDRAULIC SYSTEM
The hydraulic system on your FINN HydroSeeder
®
is designed to give trouble-free service, when
properly maintained. The most important areas of maintenance are the hydraulic oil and filtration.
The reservoir holds 8.2 gallons (31 L) of hydraulic oil. The hydraulic oil should be replaced per
the lubrication schedule or if the oil becomes milky or gives off a burnt odor. The hydraulic oil filter
must be replaced on schedule with a 5 absolute micron filter (FINN part number 023914). The
hydraulic system relief is factory-set at 2,300 psi (15,858 kPa).
At time of manufacture, this unit contains Finn Vulhydra hydraulic oil. The chart below illustrates
the operating temperature range of the Finn Vulhydra hydraulic oil as well as the closest ISO
equivalents.
NOTE:
The Finn Vulhydra hydraulic oil may be substituted for either of the two
ISO oils listed below. Please use the temperature chart to determine what
oil works best in your situation.
Summary of Contents for HydroSeeder T75S
Page 2: ...FOR OFFICE USE ONLY DATE UPDATE DESCRIPTION CODE 09 29 16 Initial release MN0929 ...
Page 4: ......
Page 39: ...33 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 40: ...34 6 1 4 5 2 7 9 2 8 3 10 9 Figure 7 Lubrication and Adjustment Points ...
Page 42: ...36 Hydro Seeder T75 13 ft 8 in 417 cm 8 ft 4 in 254 cm 5 ft 9 in 175 cm ...
Page 44: ...38 38 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 66: ...T75 CE MN0929 60 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 1 2 3 ...