PF SERIES PUMPS

PFS ATEX VERSION

(INCLUDES M6A, M6XA, M10X MOTORS & SPK)

OPERATION & PARTS MANUAL

Summary of Contents for M10X

Page 1: ...PF SERIES PUMPS PFS ATEX VERSION INCLUDES M6A M6XA M10X MOTORS SPK OPERATION PARTS MANUAL ...

Page 2: ... for any damages to people or property In case of doubt or enquiries please reply to our Technical Service department directly at the following address Finish Thompson Inc 921 Greengarden Rd Erie PA 16501 U S A Tel 1 814 455 4478 Fax 1 814 455 8518 www finishthompson com fti finishthompson com Index Introduction 1 Warranty General Terms Conditions 2 Safety 3 Pump Specifications 4 ATEX Specificatio...

Page 3: ...c 3 The warranty shall cover the replacement or repair of any part which is documented to be faulty due to construction or as sembling with new or repaired parts free of charge delivered by Finish Thompson Inc Parts subjected to normal wear and tear shall not be covered by the warranty Finish Thompson Inc shall decide as to whether the defective or faulty part shall be replaced or repaired Transpo...

Page 4: ...he pump on a regular basis to avoid any dust buildup greater than 5mm deep ALWAYS check compatibility and temperature range of pump with liquids used A Chemical Resistance and Material Selection Guide can be downloaded from our website at www finishthompson com NEVER run dry NEVER use with liquids containing solids that can damage the internals i e metal chips without optional strainer ALWAYS flus...

Page 5: ...5 F Min to 220 F Max 21 C Min to 105 C Max Wetted Materials 316 Stainless Steel Perlast PTFE ETFE 4 12 11 32 5 5 16 MODEL DIM A in DIM B in DIM C in DIM A mm DIM B mm DIM C mm PFS 27 27 29 41 3 8 685 8 737 1050 9 PFS 40 40 42 54 3 8 1016 1067 1381 1 PFS 48 48 50 62 3 8 1219 2 1270 1584 3 PFS 60 60 62 74 3 8 1524 1575 1889 1 PFS 72 72 74 86 3 8 1828 8 1880 2193 9 ...

Page 6: ...elines of the EC directive 94 9EC ATEX 100a They are intended to be used in zones 1 and 2 where explosive atmospheres are likely to occur Complete the following checklist prior to starting installation in a hazardous area All actions must be completed in accor dance with ATEX 100a Checklist for installation in hazardous areas Read motor label to check that motor has been designed for use in a haza...

Page 7: ...it per diagram located below NOTE When pumping flammable or combustible materials DO NOT operate pump unless the static protection kit is properly connected otherwise the pump motor will not comply with ATEX requirements Static Protection Kit Assembly Hose attachment to pump 1 Place the stainless steel hose clamp onto the short section of the grounded hose 2 Slide the short section of the grounded...

Page 8: ...ving container and earth ground or use a bonding wire to connect to the drum 5 Check electrical continuity of all components before pumping All should be one 1 Ohm or less 6 Avoid splashing when operating the pump Splash filling can create static electricity PFS Maintenance Disassembly 1 Remove the housing cover item 16 by turning it clockwise left hand thread while gripping the impeller housing i...

Page 9: ... item 4 into the pump head with the grooved side facing the bottom of the pump 2 If bearing assembly is replaced thread the shaft item 14 into the bearing assembly item 3 with the 3 32 hole in the shaft on the other end Carefully insert the shaft straight through the lip seal to avoid seal dam age from the top and seat the bearing assembly item 3 into the pump head 3 If o rings are replaced instal...

Page 10: ...9 PFS ATEX SPARE PARTS EXPLODED VIEW ...

Page 11: ...ELS 107616 4 72 MODELS 107616 5 10 1 PTFE SHAFT SLEEVE 27 MODELS 107615 1 40 MODELS 107615 2 48 MODELS 107615 3 60 MODELS 107615 4 72 MODELS 107615 5 11 1 BOTTOM BEARING PTFE 108195 12 1 IMPELLER HOUSING O RING PERLAST 107621 13 1 IMPELLER HOUSING Stainless steel 14 1 SHAFT 27 MODELS M100004 5 40 MODELS M100004 7 48 MODELS M100004 8 60 MODELS M100004 12 72 MODELS M100004 13 15 1 IMPELLER ASSEMBLY ...

Page 12: ...0073 5 1 HOSE FITTING J100036 6 1 MUFFLER J100033 7 2 SET SCREW J100040 8 1 AIR MOTOR MOUNT M100013 3 9 2 CAP SCREW SOCKET HEAD J100023 10 2 NUT HEX J100024 11 1 HALF COUPLING J100013 12 1 LUBRICATOR J100035 13 2 PIPE NIPPLE J102463 14 1 FILTER J100034 M6A AIR MOTOR SPARE PARTS LIST VIEW Not shown Air Motor Repair Kit J100060 11 ...

Page 13: ...TTING J100036 5 1 MUFFLER J100074 6 2 SET SCREW J100040 7 1 AIR MOTOR MOUNT M100013 4 8 2 CAP SCREW SOCKET HEAD J100023 9 2 NUT HEX J100024 10 1 HALF COUPLING J101500 11 1 LUBRICATOR J100035 12 2 PIPE NIPPLE J102463 13 1 FILTER J100034 M6XA AIR MOTOR SPARE PARTS LIST VIEW Not shown Air Motor Repair Kit J100075 12 ...

Page 14: ... motor covers labels and screws to repair the motor should it be damaged The M10X Series motor housing repair kit number is A101455 Repairs to any item other than the thermoplastic enclosure voids warranty M10X ELECTRIC MOTOR SPARE PARTS 13 ...

Page 15: ...e wires from the switch terminals Note the wire locations See figure 3 5 Press wire terminals onto the terminals of the new switch making sure they are in the correct location When the letters E T A on one side of the switch are facing up the line connectors are on the right switch termi nals and the load connectors are on the left switch terminals 6 Press the switch into slots of the aluminum hou...

Page 16: ...14 ...

Page 17: ...mp Models PFS 27 PFS 40 PFS 48 PFS 60 PFS 72 EU Directives Equipment and protective systems intended for use in potentially explosive atmospheres 2014 34 EU EU Type Examination Physical Technical testing Institute 1026 Ostrava Radvanice FTZU 04 ATEX 0293X Product Quality Assurance Notification Physical Technical Testing Institute 1026 Ostrava Radanice FTZU 08 ATEX Q 003 Applicable Harmonized Stand...

Page 18: ...ump Motor Pump Motor Models M10X EC Directives Equipment and protective systems intended for use in potentially explosive atmospheres 2014 34 EU EC Type Examination Physical Technical Testing Institute 1026 Ostrava Radvanice FTZU 08 ATEX 0083X Product Quality Assurance Notification Physical Technical Testing Institute 1026 Ostrava Radanice FTZU 08 ATEX Q 003 Applicable Harmonized Standards EN 6007...

Page 19: ...irectives Equipment and Protective Systems Intended For Use In Potentially Explosive Atmospheres 2014 34 EU Applicable Harmonized Standards DIN EN 1127 1 2011 DIN EN 13463 1 2009 DIN EN 13463 5 2011 The products are marked with the following characteristics II 2 GDc 1o C Ta 40o C Documentation archived in FTZÚ Ostrava Radviance EU code 1026 This declaration is valid provided that the devices are f...