5
SAFETY
1
. Introduction
This manual contains all the information needed for the correct installation, use, and maintenance of your new Finish Thompson
motor. It should be read and understood by all the personnel involved in installation, operating, and servicing of the pump before
it is started.
2. Operator Qualification and Training
The personnel in charge of the installation, operation and maintenance of the pump unit we produce must be quali¬fied and
able to perform the operations described in this manual. Finish Thompson Inc. shall not be held responsible for the training level
of personnel and for the fact that they are not fully aware of the contents of this manual.
3. Safety Instructions
FOR YOUR OWN SAFETY:
BEFORE UNDERTAKING ANY SERVICE OPERATION ON YOUR MOTOR OR PUMP, PLEASE MAKE SURE TO WEAR THE PROPER PRO-
TECTIVE GEAR.
GENERAL
DANGER
NEVER
perform any maintenance operation on the motor while it is running
NEVER
use a plastic pump or an open, splash-proof, TEFC or non-ATEX motor when pumping or mixing flammable or combus-
tible material. ALWAYS use and store the pump and motor in an upright position.
NEVER
immerse the motor in liquid.
ALWAYS
store motor upright and away from corrosive liquids and vapors.
ALWAYS
use an automatic air line lubricator, moisture trap and filter in the airline ahead of an air motor. (Use detergent SAE
#10 in lubricator). Do not exceed 80 psi (551 kPa) on M6 and 100 psi (689 kPa) on all other air motors.
Static sparking can cause an explosion.
Always
follow NFPA 77 and CLC/TR 60079-32-1 guidelines for control of static
electricity and proper grounding methods when using ATEX and Hazardous Location motor models. When operating in a hazard-
ous area or pumping a hazardous fluid, the motor and entire pump system must be grounded to prevent static discharge using a
Finish Thompson Static Protection Kit.
4. Noise Level
5. Modifications and Spare Parts
Any changes concerning the service of the motor as originally purchased can be executed only after written approval from Fin-
ish Thompson Inc. It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories. The use
of non-original spare parts or non-approved accessories will void warranty and removes any responsibility on our behalf for any
damage caused to people or things.
Sound Pressure Rating
Model
Air Pressure
Speed
dB(A)
S4, M6
80 PSI/5.6 bar
6,000 RPM
78
M6X, M65
100 PSI/7.0 bar
3,000 RPM
76
M66, M18
100 PSI/7.0 bar
3,000 RPM
87
M19
100 PSI/7.0 bar
3,000 RPM
90
M20
100 PSI/7.0 bar
2,500 RPM
105