Finish Thompson M Series Operation And Parts Manual Download Page 5

5

SAFETY

1

.   Introduction

 

This manual contains all the information needed for the correct installation, use, and maintenance of your new Finish Thompson 
motor. It should be read and understood by all the personnel involved in installation, operating, and servicing of the pump before 
it is started. 

2.  Operator Qualification and Training
 

The personnel in charge of the installation, operation and maintenance of the pump unit we produce must be quali¬fied and 
able to perform the operations described in this manual.  Finish Thompson Inc. shall not be held responsible for the training level 
of personnel and for the fact that they are not fully aware of the contents of this manual. 

3.  Safety Instructions
              FOR YOUR OWN SAFETY:
 

BEFORE UNDERTAKING ANY SERVICE OPERATION ON YOUR MOTOR OR PUMP, PLEASE MAKE SURE TO WEAR THE PROPER PRO-
TECTIVE GEAR.

  GENERAL 

DANGER

 

NEVER

 perform any maintenance operation on the motor while it is running

 

NEVER

 use a plastic pump or an open, splash-proof, TEFC or non-ATEX motor when pumping or mixing flammable or combus-

tible material. ALWAYS use and store the pump and motor in an upright position.

 

NEVER

 immerse the motor in liquid.

       

ALWAYS

 store motor upright and away from corrosive liquids and vapors.

       

ALWAYS

 use an automatic air line lubricator, moisture trap and filter in the airline ahead of an air  motor.  (Use detergent SAE    

       #10 in lubricator).  Do not exceed 80 psi (551 kPa) on M6 and 100 psi (689 kPa) on all other air motors.
        

Static sparking can cause an explosion.  

Always

 follow NFPA 77 and CLC/TR 60079-32-1 guidelines for control of static 

electricity and proper grounding methods when using ATEX and Hazardous Location motor models.  When operating in a hazard-
ous area or pumping a hazardous fluid, the motor and entire pump system must be grounded to prevent static discharge using a 
Finish Thompson Static Protection Kit.

4.  Noise Level

5.  Modifications and Spare Parts
 

Any changes concerning the service of the motor as originally purchased can be executed only after written approval from Fin-
ish Thompson Inc.  It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories. The use 
of non-original spare parts or non-approved accessories will void warranty and removes any responsibility on our behalf for any 
damage caused to people or things. 

Sound Pressure Rating 

Model 

Air Pressure

Speed

dB(A)

S4, M6

80 PSI/5.6 bar

6,000 RPM

78

M6X, M65

100 PSI/7.0 bar

3,000 RPM

76

M66, M18

100 PSI/7.0 bar

3,000 RPM

87

M19

100 PSI/7.0 bar

3,000 RPM

90

M20

100 PSI/7.0 bar

2,500 RPM

105

Summary of Contents for M Series

Page 1: ...M SERIES AIR MOTORS OPERATION PARTS MANUAL MODELS M6 M6X M18 M19 M20 M65 M66 for PF TB TT BT HVDP Series Pumps ...

Page 2: ...chinery safety provided pumps manufactured by Finish Thompson Inc are used This declaration is valid provided that the devices are fully assembled and no modifications are made to these devices Type of Device Air Motors for Driving Drum and Container Pumps Models M6 M6X M18 M19 M20 M57 M65 M66 S4 S4A EU Directives Machinery Safety 2006 42 EC Applied Harmonized Standards EN ISO 12100 EN 983 Manufac...

Page 3: ...onsequently Finish Thompson Inc shall not be held responsible for any damages to people or things In case of doubt or enquiries please apply to our Technical Service department directly at the following address Finish Thompson Inc 921 Greengarden Rd Erie PA 16501 U S A Tel 1 814 455 4478 Fax 1 814 455 8518 www finishthompson com fti finishthompson com Index Introduction 3 Warranty General Terms Co...

Page 4: ... sembling with new or repaired parts free of charge delivered by Finish Thompson Inc Parts subjected to normal wear and tear shall not be covered by the warranty Finish Thompson Inc shall decide as to whether the defective or faulty part shall be replaced or repaired Transportation charges are prepaid to Finish Thompson 4 The warranty of the products shall be valid for a period of 12 months from t...

Page 5: ...e motor upright and away from corrosive liquids and vapors ALWAYS use an automatic air line lubricator moisture trap and filter in the airline ahead of an air motor Use detergent SAE 10 in lubricator Do not exceed 80 psi 551 kPa on M6 and 100 psi 689 kPa on all other air motors Static sparking can cause an explosion Always follow NFPA 77 and CLC TR 60079 32 1 guidelines for control of static elect...

Page 6: ...n lubrificateur de conduite d air un piège à humidité et un filtre automatiques dans l avion devant un moteur pneumatique Utilisez le détergent SAE 10 dans le lubrificateur Ne dépassez pas 551 kPa 80 psi sur M6 et 689 kPa 100 psi sur tous les autres moteurs pneumatiques Des étincelles statiques peuvent provoquer une explosion Suivez toujours les directives NFPA 77 et CLC TR 60079 32 1 pour le cont...

Page 7: ... dommages matéri els ou corporels causés par une utilisation inappropriée de l équipement AVERTISSEMENT Il est de la responsabilité de l utilisateur de faire fonctionner la pompe conformément aux règles OSHA Santé et Sécurité au Travail relatives à la distribution de liquides Les conteneurs de pompes doivent être électriquement mis à la terre lors de l utilisation de liquides inflammables ou combu...

Page 8: ...uid to be dispensed and the hose in the container to be filled 4 While holding the air motor ball valve and hose slowly turn the valve to the desired flow rate Note Pump performance will vary depending on air pressure volume 1 Check the rotation direction of the LR motor air and induction motors before installing the motor onto the pump WARNING Motor rotation must be clockwise when viewed from the...

Page 9: ...g J100057 4 1 Ball Valve J100073 5 1 Hose Fitting J100036 6 1 Muffler J100033 7 2 Set Screw J100040 8 1 Air Motor Mount M100013 1 9 2 Socket Head Cap Screw 108392 10 2 Hex Nut J100990 11 1 Half Coupling J100013 12 1 Lubricator J100035 13 2 Pipe Nipple J102463 14 1 Filter J100034 Air Motor Repair Kit Not Shown J100060 ...

Page 10: ...Ball Valve J100073 4 1 Hose Fitting J100036 5 1 Muffler J100074 6 2 Set Screw J100040 7 1 Air Motor Mount M100013 2 8 2 Socket Head Cap Screw 108392 9 2 Hex Nut J100990 10 1 Half Coupling J101500 11 1 Lubricator J100035 12 2 Pipe Nipple J102463 13 1 Filter J100034 Air Motor Repair Kit Not Shown J100075 ...

Page 11: ... 4 J100073 1 1 Ball Valve 1 2 J100094 4 1 Muffler J100074 1 1 Muffler J100097 5 1 1 1 Motor Adapter Flange M100086 6 4 4 4 Lock Washer 3 8 J100834 7 4 4 4 Hex Head Cap Screw 3 8 J102857 8 4 4 4 Socket Head Cap Screw 1 4 J102643 9 1 1 1 Motor Adapter M100044 10 2 2 2 Set Screw J100040 1 Air Motor Repair Kit Not Shown J100100 1 Air Motor Repair Kit Not Shown J100101 1 Air Motor Repair Kit Not Shown ...

Page 12: ...ing J100036 5 1 1 Motor Adapter Flange 105111 6 1 1 Motor Adapter 105112 7 1 1 HVDP Shaft Adapter 105246 8 5 5 Socket Head Cap Screw J102643 9 3 3 Lock Washer J100672 10 2 2 Set Screw J100040 1 Air Repair Kit Not Shown J100075 1 Air Repair Kit Not Shown 108067 M65 M66 MODELS Tech Service 1 800 888 3743 techservice finishthompson com P N 110840 3 18 2019 ...

Reviews: