FTLX8561E2 Product Specification – October 2008
©
Finisar Corporation – October 2008
Rev B
Page 3
Receive Functions
Reserved
Reserved
O
O
38
39
Reserved For Future Use
Reserved For Future Use
RX LANE 0+
RX LANE 0–
O
O
41
42
Module XAUI Output Lane 0+
Module XAUI Output Lane 0–
RX LANE 1+
RX LANE 1–
O
O
44
45
Module XAUI Output Lane 1+
Module XAUI Output Lane 1–
RX LANE 2+
RX LANE 2–
O
O
47
48
Module XAUI Output Lane 2+
Module XAUI Output Lane 2–
RX LANE 3+
RX LANE 3–
AC-coupled,
Internally biased
differential
XAUI
O
O
50
51
Module XAUI Output Lane 3+
Module XAUI Output Lane 3–
DC Power
GND
0 V DC
1, 2, 3, 33, 34,
35, 36, 37, 40,
43, 46, 49, 52,
53, 54, 57, 60,
63, 66, 69, 70
Ground connection for signal ground
on the module
APS
+1.2 V
7, 8, 28, 29
Input from Adaptive Power Supply
APS SENSE
+1.2 V
27
APS Sense Output. Connected to the
APS input inside transponder.
APS SET
25
Feedback input from APS.
Connected to GND through a 1180
Ω
resistor inside the transponder.
3.3 V
+3.3 V DC
5, 6, 30, 31
DC Power Input, +3.3 V DC,
Nominal
5.0 V
+5.0 V DC
4, 32
DC Power Input, +5.0 V DC,
Nominal
Reserved
26
Reserved for APD.
Reserved
13
Reserved.