background image

FTLX1461E2 Product Specification – October 2008

   

 

 

 

©

 Finisar Corporation – October 2008  

Rev B 

 

Page 10 

Package Outline 

 

Figure 2-XENPAK Mechanical Dimensions 

 

IX.

 

References 

The following references are provided for informational purposes only.  The parameters and 
operational behavior outlined in this specification describe the complete functionality of the 10G 
Transponder.  Contact Finisar for any items concerning the operational characteristics of this 
device. 
 

ƒ

 

IEEE Std 802.3ae-2002 clause 52, 10GBASE-LR 

ƒ

 

XENPAK MSA Issue 3.0 

 

X.

 

For More Information 

 

 

Finisar Corporation 
1389 Moffett Park Drive 
Sunnyvale, CA  94089-1133 
Tel. 1-408-548-1000 
Fax 1-408-541-6138 

[email protected]

 

www.finisar.com

 

 

 

Summary of Contents for Single Mode XENPAK Transponder FTLX1461E2

Page 1: ...e range 0 C to 70 C Transmission distance of 10km Uncooled directly modulated 1310nm Distributed Feedback DFB laser SC connector single mode fiber Full duplex transmission mode Digital Optics Monitoring DOM Power supply 5 0 V 3 3 V Adaptable Power Supply APS 1 2 V XAUI electrical interface 4 x 3 125 Gb s Ethernet Management and control via MDIO 2 wire bus 70 pin connector Separated signal chassis ...

Page 2: ...ET Open Drain I 10 Reset Input Open Drain Compatible Input with 22 kΩ pull up to APS internal to transponder Logic high Normal Operation Logic low RESET Vendor Specific 11 15 16 24 Vendor Specific Pins Leave unconnected when not used TX ON OFF Open Drain I 12 TX ON OFF Input Open Drain Compatible Input with 22 kΩ pull up to APS internal to transponder Logic high Transmitter On Logic low Transmitte...

Page 3: ... RX LANE 3 AC coupled Internally biased differential XAUI O O 50 51 Module XAUI Output Lane 3 Module XAUI Output Lane 3 DC Power GND 0 V DC 1 2 3 33 34 35 36 37 40 43 46 49 52 53 54 57 60 63 66 69 70 Ground connection for signal ground on the module APS 1 2 V 7 8 28 29 Input from Adaptive Power Supply APS SENSE 1 2 V 27 APS Sense Output Connected to the APS input inside transponder APS SET 25 Feed...

Page 4: ... Values Parameter Symbol min max Unit Storage Ambient Temperature1 TS 40 85 C Operating Case Temperature1 TC 0 70 C Supply Voltage 5 0 V V5 0 6 V Supply Voltage 3 3 V V3 0 4 V Supply Voltage APS Vaps 0 1 5 V Static Discharge Voltage All Pins2 STd 500 V Average Receive Optical Power RxP max 1 5 dBm Notes 1 Non condensing 2 HBM Exceeding any one of these values may permanently destroy the device ...

Page 5: ...typ max Unit 1 2 V CMOS 1 8 V CMOS Compatible1 I O DC Characteristics PRTAD LASI RESET TX_ONOFF External Pull up Resistor for Open Drain Rpullup 10 22 kΩ Output High Voltage2 Voh 1 V Output Low Voltage2 Vol 0 15 V Input High Voltage Vih 0 84 1 5 V Input Low Voltage Vil 0 36 V Input Pull down Current3 Ipd 20 120 µA XAUI I O DC Characteristics TXLANE 0 3 RXLANE 0 3 Differential Input Amplitude pk pk...

Page 6: ...istics RXLANE 0 3 Baud Rate Ethernet RXAUIOUT 3 125 Gbit s Baud Rate Variation RXAUIVAR 100 100 ppm XAUI Eye Mask far end According to IEEE 802 3ae Output Differential Skew tSKEWOUT 15 ps Output Differential Impedance ZOUTXAUI 80 100 120 Ω Differential Output Return Loss1 S22 10 dB Total Jitter4 TJXAUI 0 35 UI Deterministic Jitter4 DJXAUI 0 37 UI Power On Reset AC Characteristics Power On Reset an...

Page 7: ...tance REFTX 12 dB Eye Mask Definition According to IEEE 802 3ae Receiver Stressed Receiver Sensitivity in OMA PIN S 10 3 dBm Rx Sensitivity in OMA1 PIN O 12 6 dBm Average Receiver Power1 PIN 14 4 0 5 dBm Receiver Damage Power PIN dmg 1 5 dBm Signal Detect Assert Level PLOSa 13 dBm Signal Detect Hysteresis PLOSh 1 dB Receiver Reflectance REFRX 12 dB Receive Electrical 3dB Upper Cutoff Frequency FC ...

Page 8: ...ash Finisar XENPAK transponders are neither solderable nor aqueous washable and are not intended for these processes VI Regulatory Compliance Feature Standard Comments ESD Electrostatic Discharge to the Electrical Pins HBM EIA JESD22 A114 B MIL STD 883D Method 3015 7 Class 1a 500 V Immunity Against Electrostatic Discharge ESD to the Module Receptacle EN 61000 4 2 IEC 61000 4 2 Discharges ranging f...

Page 9: ...1 Electrical Safety UL CSA CLASS 3862 07 CLASS 3862 87 1439230 Copies of the referenced certificates are available at Finisar Corporation upon request VII DOM Parameters VIII Mechanical Characteristics Values Parameter Symbol min typ max Unit Module Retention Force latch strength FRET 200 N Module Insertion Force FIN 40 N Module Extraction Force with kick out FEXT K 16 N Module Extraction Force wi...

Page 10: ...rameters and operational behavior outlined in this specification describe the complete functionality of the 10G Transponder Contact Finisar for any items concerning the operational characteristics of this device IEEE Std 802 3ae 2002 clause 52 10GBASE LR XENPAK MSA Issue 3 0 X For More Information Finisar Corporation 1389 Moffett Park Drive Sunnyvale CA 94089 1133 Tel 1 408 548 1000 Fax 1 408 541 ...