15
CONTENTS
Deleting attendance logs in m-Kadex
In standby mode, the m-Kadex’s LED blinks in green > Wave the administrator card 7
times at the induction area > The LED will lit up in green to indicate that the deletion
process is running > The LED will blinks in green once > the process is completed
Resetting to Default Factory Settings using
Administrator Card
Green LED blinks > Wave Administrator card 5 times at the induction area > The terminal
beeps 3 times > Red LED blinks > Wave the Administrator card once at the induction
area to confirm > Green LED blinks > Terminal beeps continuously for 7 seconds> Green
LED blinks
Remark:
All contents in the terminal will be deleted including the content in administrator card. The
IP address of the terminal returns to default 192.168.1.201 after this process. The Terminal ID returns to
1 after this process.
Resetting to Default Factory Settings Without
Administrator Card
Green LED blinks > Detach the terminal from its location on a wall > Release the security
button > Wait for 30 sec > Push and release the security button 3 times > Terminal pro-
duces a long beep > restart the terminal