17
11.1 Simulation output test
1. Finished the installation and supply the sensor with 12~30Vdc.
2. Lean a magnet close to the + sing for 3 seconds
or more, there will be switching output with
corresponding LED light display.
3. Remove the magnet from the + sign, the
switching output and corresponding LED light
display will return to normal status.
4. Magnetic(min 100GS@10mm)is in use.