08-EB5XXX-B1-EM, 03/10/2014
RF Admittance Level Transmitter
Operation Manual
Thank for buying FineTek's products. Please
read the user manual first before using it. It
is important to be familiar with product's
performance and function. Please keep the
user manual for operation reference.
EB5 Series
WORKING PRINCIPLE
OSC
CPU
Voltage
regulator
Signal
output
RF Admittance
Level Transmitter
Tank
Sensing probe
24Vdc
A
10%
DESCRIPTION OF PANEL
PF & ACCURACY CHART
SPECIFICATION
18~30Vdc
4~20mA (
)
2 wire
20mA
4mA
Option
A
1%F.S. or
0.5pF
A
-40
B
C~85
B
C
0~85% RH, non-condensing
<
A
0.2% F.S. per
B
C or 0.1pF per
B
C
-1999~9999
IP 65
20~2000pF
<(Vs-22)
H
50
W
Vs: Power Voltage (volt)
According to the specification of probe
Power supply
Measuring range
Output current
Upper limit
Lower limit
HART
Linearity
Load resistance
Environment
temperature
Operation
temperature
Environment
humidity
Temperature
coefficient
LCD Display
range
Protection degree
DESCRIPTION OF PANEL
DESCRIPTION OF PARAMETERS
PROGRAM SETTING FLOW CHART
DESCRIPTION OF ALARM MODES
LCD display
"UP" button
"Shift" button
"Enter" button
Power supply
LEVE
L
E
C
TR
N
A
A
T
N
T
S
I
M
M
I
D
TT
A
E
F
R
R
Display value
2sec
Error Message
Correction
No Display
Display "-1"
Display "1"
Display "Over"
"SPAN" ,"WARN"Glisten
Display "NULL"
The output change rapidly
when level disturbance
The output change rapidly
when level is stable(<3%)
The output change rapidly
when level is stable(>3%)
The output is not porpotional
to the level
The LCD Display low point but the
display on the Panel at control
is not equal low point
The LCD Display
but the
display on the Panel at control
is not equal high point
high point
Make sure the power supply
24V
±
10%
Recalibrate LOPT
Recalibrate HIPT
The capacitance is too much , please select plastic coating version,
or caused to short between probe and wall.
The output is latched , enter CTRL LACH to turn off this function
The output range is smaller than 20Pf, Adjust range to low level and recalibrate it
There is shortcut between probe and tank wall, please recheck the installation
Increase "DAMP"value
Set "FILT" to HI ,increase the frequence of filter
1. Enter manu"CAP" to check if the value change
2.When level remains , but the value change <1pF , please recalibrate HIPT &LOPT
3.When level remains, but the value change >1pF , please recheck the wiring.
Enter the manu to E_4, If the display at the control room >
, decrease
E_4 value ;if the display at the control room< low point , increase E_4 value
low point
Enter the manu to E_20, If the display at the control room >
, decrease
E_20 value ;if the display at the control room<high point, increase E_20 value
high point
Remark 1: Please refer to calibration procedure for HIPT & LOPT setting.
Remark 2:
Remark 3:
Remark 4:
The output is latched when display is up to 110% or -10%
Re-calibration is essential when the measuring range is revised.
When calibrating 4 .20mA, 0.24uA per step will be changed
when press up bottom once.
0~3
-1999~9999
-1999~9999
DOT1
100.0
0
100.0
0.0
ON, OFF
1~60sec
OFF
1
SAVE,RSET
BACK
SAVE,RSET
BACK
Lo,MID,HI
SAVE
SAVE
LO
-1999~9999
-1999~9999
0~9999
0~9999
400
0~9999
200
-1999~9999 0
-1999~9999 0
LO,MID,HI
HI
Measuring range remark 3.
Decimal point setting
20mA corresponding
display value
4mA corresponding
display value
Corresponding calibration value for
high point (Hipt). See remark 1
Corresponding Calibration Value for
low point (Lopt). See remark 1
Memory for max & mini value
during operation.SAVE:Save value
into Eeprom
REST:Clear present value and
memoryBACK:Go back to sub-menu
Output latch enable or disable.
See remark 2.
Software Filter
Display current capacitance value
High point Capacity Value
4mA micro setting value
20mA micro setting value
Default
Output updated time
Main
Menu
Sub-
Menu
Range
Default
Description
1. Button Protection, requiring to press ENT+UP
buttons for 2 seconds in order to get into main menu.
2. Three input buttons; user-friendly.
3. Any two points for calibration
4. Retention for maximum and minimum values.
Low point Capacity Value
When the probe is surrounding by the air , little capacitance
(C ) is measured by the equivalent capacitor , the
A
capacitance increase gradually as computing media, the
max. capacitance (C ) will be measured while the tank is
B
full, the difference (dC)between C and C is proportional to
A
B
the level.
=25 ~2000 pF)
(Recommend range dC
"LACH" "1234"
Y:
Z:
Y:
Z:
G:
L:
H:
J:
K:
I:
G:
L:
H:
J:
K:
I:
B:
C:
E:
A:
F:
D:
B:
C:
E:
A:
F:
D:
Q:
R:
M:
O:
P:
N:
Q:
R:
M:
O:
P:
N:
V:
W:
T:
U:
S:
X:
V:
W:
T:
U:
S:
X:
Output
Try to calibrate at 0% & 100% , the accuracy is higher when the setting is closer to 0%&100%
CODE
(PF)
A
c
c
u
ra
c
y
(%
)
500
1000
1500
2000
2500
0.0%
0
100
0.1%
0.2%
0.3%
0.4%
0.5%
0.6%
0.7%
0.8%
0.9%
1.0%
5.0%
LCD monitor: -20
B
C~85
B
C