08-EB5XXX-B1-EM, 03/10/2014

RF Admittance Level Transmitter 

Operation Manual

Thank for buying FineTek's products. Please 
read the user manual first before using it. It 
is important to be familiar with product's 
performance and function. Please keep the 
user manual for operation reference.

EB5 Series

WORKING PRINCIPLE

OSC

CPU

Voltage 
regulator

Signal 
output

RF Admittance 

Level Transmitter 

Tank

Sensing probe

24Vdc

A

10%

DESCRIPTION OF PANEL

PF & ACCURACY CHART

SPECIFICATION

18~30Vdc

4~20mA (

)

2 wire

20mA

4mA

Option

A

1%F.S. or 

0.5pF

A

-40

B

C~85

B

C

0~85% RH, non-condensing

<

A

0.2% F.S. per 

B

C or 0.1pF per 

B

C

-1999~9999

IP 65

20~2000pF 

<(Vs-22)

H

50

W

    Vs: Power Voltage (volt)

According to the specification of probe

Power supply

Measuring range

Output current

Upper limit

Lower limit

HART

Linearity

Load resistance

Environment 
temperature

Operation 
temperature

Environment 
humidity

Temperature 
coefficient

LCD Display 
range

Protection degree

DESCRIPTION OF PANEL

DESCRIPTION OF PARAMETERS

PROGRAM SETTING FLOW CHART

DESCRIPTION OF ALARM MODES

LCD display

"UP" button

"Shift" button

"Enter" button

Power supply

LEVE

 

L

E

 

C

TR

N

A

A

T

N

T

S

I

M

M

I

D

TT

A

 

E

F

R

R

Display value

2sec

Error Message

Correction

No Display

Display "-1"

Display "1"

Display "Over" 

"SPAN" ,"WARN"Glisten

Display "NULL"

The output change rapidly 
when level disturbance

The output change rapidly 
when level is stable(<3%)

The output change rapidly 
when level is stable(>3%)

The output is not porpotional 
to the level

The LCD Display low point but the 
display on the Panel at control 
is not equal low point 

The LCD Display 

but the 

display on the Panel at control 
is not equal high point

high point 

Make sure the power supply 

24V

±

10%

Recalibrate LOPT 

Recalibrate HIPT 

The capacitance is too much , please select plastic coating version, 
or caused to short between probe and wall.

The output is latched , enter CTRL       LACH to turn off this function

The output range is smaller than 20Pf, Adjust range to low level and recalibrate it

There is shortcut between probe and tank wall, please recheck the installation

Increase "DAMP"value

Set "FILT" to HI ,increase the frequence of filter

1. Enter manu"CAP" to check if the value change
2.When level remains , but the value change <1pF , please recalibrate HIPT &LOPT 
3.When level remains, but the value change >1pF , please recheck the wiring.

Enter the manu to E_4, If the display at the control room >

 , decrease 

E_4 value ;if the display at the control room< low point , increase E_4 value

 low point 

Enter the manu to E_20, If the display at the control room >

, decrease 

E_20 value ;if the display at the control room<high point, increase E_20 value

 high point 

Remark 1: Please refer to calibration procedure for HIPT & LOPT setting.
Remark 2: 
Remark 3: 
Remark 4: 

The output is latched when display is up to 110% or -10%
Re-calibration is essential when the measuring range is revised.
When calibrating 4 .20mA, 0.24uA per step will be changed 

                 when press up bottom once.

0~3

-1999~9999

-1999~9999

DOT1

100.0

0

100.0

0.0

ON, OFF

1~60sec

OFF

1

SAVE,RSET 
BACK

SAVE,RSET 
BACK

Lo,MID,HI

SAVE

SAVE

LO

-1999~9999

-1999~9999

0~9999

0~9999

400

0~9999

200

-1999~9999 0

-1999~9999 0

LO,MID,HI

HI

Measuring range remark 3.

Decimal point setting

20mA corresponding 
display value
4mA corresponding 
display value
Corresponding calibration value for 
high point (Hipt). See remark 1
Corresponding Calibration Value for 
low point (Lopt). See remark 1

Memory for max & mini value 
during operation.SAVE:Save value
into Eeprom
REST:Clear present value and 
memoryBACK:Go back to sub-menu

Output latch enable or disable. 
See remark 2.

Software Filter

Display current capacitance value

High point Capacity Value

4mA micro setting value

20mA micro setting value

Default

Output updated time

 

Main 
Menu

Sub-
Menu

Range

Default

Description

1. Button Protection, requiring to press ENT+UP 
    buttons for 2 seconds in order to get into main menu. 
2. Three input buttons; user-friendly.
3. Any two points for calibration
4. Retention for maximum and minimum values. 

Low point Capacity Value

When the probe is surrounding by the air , little capacitance 
(C  ) is measured by the equivalent capacitor , the 

A

capacitance increase gradually as computing media, the 
max. capacitance (C ) will be measured while the tank is 

B

full, the difference (dC)between C  and C  is proportional to 

A

 

B

the level. 

 =25 ~2000 pF)

(Recommend range dC

"LACH"       "1234"

Y: 

Z:

Y: 

Z:

G: 

L: 

H:  

J: 

K: 

I: 

G: 

L: 

H:  

J: 

K: 

I: 

B: 

C: 

E: 

A: 

F: 

D: 

B: 

C: 

E: 

A: 

F: 

D: 

Q: 

R: 

M: 

O: 

P: 

N: 

Q: 

R: 

M: 

O: 

P: 

N: 

V: 

W: 

T: 

U: 

S: 

X: 

V: 

W: 

T: 

U: 

S: 

X: 

Output

Try to calibrate at 0% & 100% , the accuracy is higher when the setting is closer to 0%&100%

CODE

(PF)

A

c

c

u

ra

c

y

(%

)

500

1000

1500

2000

2500

0.0%

0

100

0.1%

0.2%

0.3%

0.4%

0.5%

0.6%

0.7%

0.8%

0.9%

1.0%

5.0%

LCD monitor: -20

B

C~85

B

C