Finest Security Systems SP-A016AH Manual Download Page 3

 

3

 

 

2.

 

RS485 Remote Control Setting:   

 
This device could use command line to control via built in RS485 terminal program, (CLI

Command-Line Interface), through RS485 terminal port (Console Port) for detailed function 
setup and management. You could use our model number: RS003 USB to RS485 converter, or 
RS001 RS232 to RS485 converter, the Communication format is 9600,8, N, 1 (9600 bps, 1 start 
bit, 8 data bits, 1 stop bit). 

 
Use command as below

 

 

 

Display command usage 

 
* n 

 Control device number (Device No), n = 0-32, Without input parameter: Display the device 
number 
Once the setting device into control mode, If you do not do any operation within 1 minutest, it 

will auto off control mode. 

 
# n   

 

Control channel number (Channel No)

n = 1-16

 

                          Without input parameter: Display current setting     
   
SET n 

 

Setting this device number, n = 0-32, 0 mean stand alone mode (Factory Default) 

Do not repeat setting the device number, recommend setting an individual connection to 
RS485, not to connect other devices in series in order to avoid any confusion at the setting 
number.   

 

 
STATUS n 

Display the current control device channel status 
n = 0      display all channel status   
n = 1-16 display the specified channel status 

 

 

        Without input parameter: Display current control channel status 

 

AUTO 

 

Setting auto gain mode (Factory Default) 

 
MANUAL         Setting manual Equalization mode. 
 
LENGTH n 

Manual setting Equalization mode for different cable distance (Sharpness), n = 0-63 (Factory 
Default is 0)

1 step equal 25 METERS. Without input parameter: Display current setting. 

 
GAIN n 

 Manual setting Equalization mode for different gain control (Brightness), n = 0-63 (Factory 
Default is 32), 0 is the darkest value

63 is the brightness value.    Without input parameter: 

Display current setting. 

 
COLOR n 

Input video signal format 

n = 0 is mono video signal   

IR Remote Control   

Termination Resistors 

 

32 

RS003 / RS001 

Summary of Contents for SP-A016AH

Page 1: ... with 2 outputs 16 UTP inputs to 32 BNC outputs Built in surge protection This device auto gain operation by factory default For any abnormal picture occurred it could be using RS485 terminal or IR remote control for advanced management setup and control Built in RS485 terminal for advanced management setup and control It could be daisy chain up to 32pcs of SP A016AH by any one option remote PC mo...

Page 2: ... to use adjust the cable distance setting total 64 adjustments B Manual setting Equalization mode for different gain control Brightness Press B to use adjust the gain setting total 64 adjustments MENU 1 ENTER Setting auto gain mode Factory Default MENU 2 ENTER Setting manual Equalization mode MENU 3 0 ENTER Setting input signal as color signal and make Equalization for color signal MENU 3 1 ENTER ...

Page 3: ...and alone mode Factory Default Do not repeat setting the device number recommend setting an individual connection to RS485 not to connect other devices in series in order to avoid any confusion at the setting number STATUS n Display the current control device channel status n 0 display all channel status n 1 16 display the specified channel status Without input parameter Display current control ch...

Page 4: ...ailed control and management 2 Please remember save any new change setting in order to operate the new setting correctly 3 If using multiple SP A016AH with RS485 series control the last SP A016AH device must add 120Ω termination resistors at terminal port Console Port in order to stabilize the data signal 4 Long distance transmission or have interference occurred that might cause Equalization func...