Replacing your filters- 

(Filters only, not membrane)-  

Please have some towels and cloths ready as some water will 
escape from the unit.  

Turn off the water by putting the isolator tap to ‘off’ position (1/4” turn 
from on position).  

Drain as much water from the unit as possible. 

*REMOVE THE MEMBRANE FROM THE HOUSING AND SET 
ASIDE UNTIL FILTERS HAVE BEEN CHANGED AND THE UNIT 
FLUSHED* 

Remove the collet clips from the fitting and using the quick release, 
remove the tubing on both sides. (Lift filter off bracket if easier). 

Un-screw the fittings from the end of the inline filter. Dispose of 
exhausted filter. 

Remove any residual PTFE tap from the male thread of the fittings.  

Using PTFE tape, thread 15-20 wraps of PTFE tap around the male 
end of both fittings.  

Remove the new inline filter from the packaging and screw the fittings 
back in place. Ensure the filter is the correct way by the flow arrow.  

Put filter back in place and re-insert the tubing and collet clip and pull 
back to ensure inserted correctly.  

Do this for all the filters and carry out 1

st

 System Flush from page 9.  

Carefully add membrane back into the housing.   

Replacing Filters and Membrane 

–  

Please carry out all steps from the Replacing Filters section and carry 
out the 1

st

 flushing stage.  

Follow the instructions for inserting your membrane on page 9 then 
carry out the 2

nd

 flushing stage to complete the filter and membrane 

changes.   

 

Summary of Contents for RO-H-100G

Page 1: ...1704 807600 www finerfilters co uk enquiries finerfilters co uk Compact Reverse Osmosis System Installation and Maintenance Manual For Systems RO H 50G RO H 75G RO H 100G RO H1 50G RO H1 75G RO H1 100...

Page 2: ...1 Contents 1 General Information Page 2 2 System Layout and Components Page 3 3 Preparation Page 4 4 Installation Page 6 5 Maintenance Page 10 6 Replacement Filters Page 11 7 Troubleshooting Page 12...

Page 3: ...bstances heavy metals soluble solids bacteria viruses pyrogen nitrate microorganisms hormones Fluoride and other harmful impurities It only retains water molecules and dissolved oxygen To achieve this...

Page 4: ...aining ions Main Technical Parameter 1 Purified water output based on optimal water pressure 50GPD membrane 185L day 75GPD membrane 275L day 100GPD membrane 370L day 2 Inlet water temperature 4 42 C 4...

Page 5: ...0G RO H1 50G RO H1 75G RO H1 100G A Three way valve B Ball valve C PP sediment filter cartridge D Carbon inline filter cartridge E RO membrane housing F RO membrane G Flow restrictor 4 Stage Unit Incl...

Page 6: ...crewdriver Plastic tube cutter Stanley Blade The 5 metres of tubing provided is to be used at the points marked by the coloured stoppers on the RO system Mark 1 Red stopper Cold water supply to RO sys...

Page 7: ...move collet clip insert tubing into fitting until it locks Gently pull tubing back to ensure fit is secure Re place collet clip How to disconnect See Fig 4 Remove collet clip push down on collet so it...

Page 8: ...2 Using the white or black fitting screw on to the male thread of the isolator body and push copper pipe into the both sides of the fitting Ensure all fittings are secure A garden tap fitting is also...

Page 9: ...this step Connect system Determine length of tubing needed between RO system and mains water supply and remove red stopper on unit Connect tubing from cold water supply drain clamp and water outlet t...

Page 10: ...tubing where the leak was found Also see our troubleshooting section at the back of the manual Once the issue is resolved start process again Turn off the mains water by the isolator and let the wate...

Page 11: ...the isolator tap to on position 1 4 turn from off position You will hear the RO unit starting to produce water Double check the unit for leaks As per 1st system flush Run the water from the RO unit fo...

Page 12: ...move chorine and to improve taste and odour 6 Months RO Membrane To remove foreign particles soluble solid bacteria and virus from raw water 1 3 years Post DI Filter 4 Stage Only To remove ions from t...

Page 13: ...Remove any residual PTFE tap from the male thread of the fittings Using PTFE tape thread 15 20 wraps of PTFE tap around the male end of both fittings Remove the new inline filter from the packaging a...

Page 14: ...ow 1 Pre or post filter clogged 1 Check replace pre or post filter Pre or post filter leaking 1 Tubing not inserted fully 1 Remove tubing ensure end is straight Insert and gently pull back on tubing t...

Page 15: ...e insert membrane on pg 11 Cloudy milky water 1 Defective membrane 2 New filters or membrane 1 Replace if TDS reading is below 85 2 Flush system through Leaking fitting 1 Fitting damaged or cracked 2...

Reviews: