6
1.4. Installation and Functional Check
1)
Maintain the conveyor of automatic weight sorting device level with ground by all means.
For adjustment to level condition, tighten up fixing nut to prevent shaking while
adjusting the four legs mounted at the bottom of automatic weight sorting device to level
condition.
2) Vibration and wind etc may cause measurement error. Take caution to keep off such
elements.
3) For smooth entrance and discharge of measured object, place each conveyor in cascade
style. For stable measurement, place entrance part conveyor 0.5 to 1.0mm above
measurement part. If the height is low, shock may be applied to measurement part when
measured object enters followed by weight measurement error and reduction of weight
sensor lifespan.
4) Used Voltage: Single phase AC220V 50/60Hz
±
10% (For other specification, contact head
office.)
* Install the instrument in separation from power.
* Install ground by all means.
4) Optimum Temperature: 5
℃
~35
℃
[41
℉
~95
℉
],
±
2
℃
/hr
5) Optimum Humidity: 35
%
~ 85
%
RH
6) Function Check
①
Perform checking of functions frequently as well as test-driving and re-installation.
②
Check for presence of abnormality of lamp, motor, air solenoid valve and boozer.
③
Keep conveyor clean off foreign matters.