Fine Offset Electronics WN30BN User Manual Download Page 2

 

   

 

 

 

Page 2 

3.

 

Getting Started 

The WN30BN probed thermometer includes the following: 

3.1

 

Parts List 

QTY 

Item 

Probed Thermometer (LxHxW): 4.75 x 1.5 x 0.6 in (12 3x 42 x 14 mm) 

User Manual 

3.2

 

Recommend Tools 

 

Drill for mounting screw 

4.

 

Setup Guide 

4.1

 

  Batteries and Dip Switches 

The  WN30BN  probed  thermometer  requires  2  x  AA  batteries  (not  included).  We  recommend 
Energizer Lithium batteries for longer life and a wider operating temperature range. 
 

1.

 

Remove the battery door on the back of the transmitter(s) by sliding down the battery door, as 
shown in Figure 2 .   

 

 

Figure 2 

 

2.

 

BEFORE

 inserting the batteries, locate the dip switches on the inside cover of the lid of the 

transmitter. 

 

3.

 

Channel Number:

 The WS-2000 and WS-5000 supports up to eight transmitters. To set each 

Summary of Contents for WN30BN

Page 1: ...atement 6 1 Introduction Thank you for your purchase of the WN30BN probed thermometer The following user guide provides step by step instructions for installation operation and troubleshooting The sensor is not a stand alone device and requires a WS 290B or greater revision WS 2000 or WS 5000 weather station to view and upload the data to our cloud hosting service 2 Features 10 water proof probed ...

Page 2: ...30BN probed thermometer requires 2 x AA batteries not included We recommend Energizer Lithium batteries for longer life and a wider operating temperature range 1 Remove the battery door on the back of the transmitter s by sliding down the battery door as shown in Figure 2 Figure 2 2 BEFORE inserting the batteries locate the dip switches on the inside cover of the lid of the transmitter 3 Channel N...

Page 3: ... 3 Switch in down position Switch in up position Figure 3 5 Insert two AA batteries 6 Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 4 Figure 4 1 temperature units F vs C 2 temperature 3 channel number 7 Close the battery door 8 Repeat for the additional remote transmitters verifying each remote is on a different channel 5 Sensor ...

Page 4: ...ess phones wireless routers TVs and computer monitors and transmission barriers such as walls In general wireless signals will not penetrate solid metal and earth down a hill for example The following is a table of reception loss vs the transmission medium Each wall or obstruction decreases the transmission range by the factor shown below Medium RF Signal Strength Reduction Glass untreated 5 15 Pl...

Page 5: ... the specifications for the measured parameters Measurement Range Accuracy Resolution Probe Temperature 40 to 140 F 2 F 0 1 F 7 3 Power Consumption 2 x AA batteries not included 8 Liability Disclaimer Please help in the preservation of the environment and return used batteries to an authorized depot The electrical and electronic wastes contain hazardous substances Disposal of electronic waste in w...

Page 6: ...pressly approved by this company could void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment ...

Reviews: