TECHNICAL FEATURES
Power supply:
4 alkaline batteries 1.5V type AA
Temperature adjustment WINTER:
(+5…+37)°C
Temperature adjustment SUMMER:
(+5…+37)°C
Resolution:
0.1°C
Tolerance:
+/– 0.5°C at 20°C
Differential:
Self-adjusting by product and adjustable by APP
Operation mode:
Summer
-
Winter
-
Auto
-
Manual
-
OFF
Degree of protection:
IP20
PIN lock:
yes, by Finder Bliss App
Output:
5 A 250 V AC volt-free changeover contact
Mounting:
Wall
2
DIMENSIONS
SAFETY REQUIREMENTS
The installation and assembly of electrical equipment must be performed
by expert personnel. Before connecting the chronothermostat make sure
that the load (pumps, valves, boiler, etc ...) are not powered-up and are
within the rating of the contact.
To remove the base use the appropriate slots
1
and
2
INSTALLATION NOTES