Fimer PVS-50-TL Quick Installation Manual Download Page 3

3

3.  Inverter models and components

The inverter model should be chosen by a specialized technician who has a good knowledge of the installation conditions, the devices that will be installed 

externally, and whether it will eventually be integrated into an existing system. 

The following models of inverter are available:

Inverter model

Input channel DC switch DC SPD DC connection

String fuses

AC SPD

Display

DC SPD 

class 1+2

PVS-50(60)-TL

1

No

Class 2 screw terminal blocks

No

Class 2

optional

No

PVS-50(60)-TL-SX

3 (1 if paralleled) Yes

Class 2 15 pairs quick fit connectorsPositive

Class 2

optional

No

PVS-50(60)-TL-SX2

3 (1 if paralleled) Yes

Class 2 15 pairs quick fit connectorsPositive and negative Class 2

optional

optional

Main components
01

Bracket

19

Input quick fit connectors ( channel 1)

50

Parallel MPPT connection points

02

Locking brackets

20

Input quick fit connectors ( channel 2)

51

ALARM (multifunction relay) terminal block

03

Inverter/bracket anchor points

21

Input quick fit connectors ( channel 3)

52

AUX (multifunction relay) terminal block

04

Wiring box front door

22

Anti-condensation valve

53

RS485-1 and RS485-2 lines, R1ON/OFF and R2ON/OFF 

(remote ON/OFF) and 5V auxiliary lines terminal block

05

LED panel

23

Cooling section

06

Display

24

Lower support

54

RS485-1 line 120Ohm termination resistor switch

07

Keypad

30

Communication and control board

55

RS485-1 communication card housing

08

Keylock

31

Grounding kit (optional kit)

56

RS485-1 line connection on RJ45 connector

09

Lifting ring

32

DC overvoltage surge arresters

57

RS485-2 line connection on RJ45 connector

10

Wi-Fi antenna connector

33

DC disconnect switch

58

RS485-2 line 120Ohm termination resistor switch

11

Locking brakets attachment point

34

Negative (-) side string fuses

59

RS485-2 communication card housing

12

Ethernet cable gland

35

Positive (+) side string fuses

60

RS485 Main terminal block ( J5)

13

Service cable gland

36

AC overvoltage surge arresters

61

Battery housing

14

Handle

37

Protective earth terminal (internal)

62

SD card housing

15

DC disconnect switch

38

AC output screw terminal block

63

Grounding kit connector (optional kit)

16

Protective earth terminal (external)

39

DC input screw terminal block

64

Inverter data memory card housing

17

DC cable glands

40

AC filter board

65

Ethernet connector

18

AC cable gland

41

Parallel MPPT connection points

OFF

ON

OUTPUT AC

INPUT

DC

OUTPUT AC

INPUT

DC

PVS-60

INPUT

DC

1A

1B

1C

1D

1E

2A

2B

2C

2D

2E

3A

3B

3C

3D

3E

Inverter (external view)

PVS-50/60-TL

09

11

14

11

24

22
23

22
23

18

21

20

19

18

17

24

11

16

15

14

13

12

05

05

09

09

10

11

06 07

PVS-50/60-TL-SX / PVS-50/60-TL-SX2

08

38

37

40

36

30
31
41
32
33
34
35

38

37

40

36

30
31
41
32
33
35

PVS-50-TL 

PVS-60-TL

36

40

37
38

39

32

31

30

PVS-50-TL-SX 

PVS-60-TL-SX

PVS-50-TL-SX2 

PVS-60-TL-SX2

  READ THE MANUAL  – 

E

See the manual for details on the connections and functions available on the communication and control board.

The illustration shows the main components and connections available on the communication and control board 

(30)

. Each connection cable reaches 

the communication board through service cable glands 

(13)

 and Ethernet cable gland 

(12)

 .

J1

J8

X5

J9

J10

J11

J12

J16

A5

J14

J13

S6

J20

J17

J21

J7

J2

S5

J5

J24

K5

S9

S8

T5

J27

J6

J19

J22

K6

J25

J3

89

0

5 6

7

NC

COM

NO

NC

COM

NO

12

3

4

12

3

4

89

0

5 6

7

OFF

ON

PC2

 

 

OFF

ON

PC1

Communication and control board (30) 

61

64

60

58

65

50

51

52

53

54

55

56

57

59

62

63

Summary of Contents for PVS-50-TL

Page 1: ...allation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective APPLY HERE THE WIRELESS IDENTIFICATION LABEL ...

Page 2: ...ow of air around the inverter is not blocked so as to prevent overheating Do not install near flammable substances minimum distance 3 m Do not install near on wooden walls or near flammable surfaces Do not install in rooms where the people live or where the prolonged presence of people or animals is expected Installation of these models can be carried out vertically or horizontally with a maximum ...

Page 3: ... connector 33 DC disconnect switch 58 RS485 2 line 120Ohm termination resistor switch 11 Locking brakets attachment point 34 Negative side string fuses 59 RS485 2 communication card housing 12 Ethernet cable gland 35 Positive side string fuses 60 RS485 Main terminal block J5 13 Service cable gland 36 AC overvoltage surge arresters 61 Battery housing 14 Handle 37 Protective earth terminal internal ...

Page 4: ...rminal internal 37 2x Protective earth terminal external 16 4 Configuration bar for paralleled input channels and M5x12 screws with plain and split washers 1 3 Key for front door key lock 8 Technical documentation 1 6 Mounting instructions The mounting bracket 1 can be used to install the inverter on a vertical or horizontal support 1 Position the bracket 1 perfectly level on the support and use i...

Page 5: ...nsert must be installed on the cable FIG 9 As alternative is possible to connect the earth cable to the protective earth terminal external 16 positioned on the left side of the mechanics As per the protective earth terminal internal 37 following to the sequence illustrated in the below figure and tightening it to a torque of 11Nm A ring cable lug suitable for aM6 size threaded insert must be insta...

Page 6: ... with a display the error message appears on the display READ THE MANUAL E Refer to the product manual for a description of error warning codes appearing on the display for inverters with a display 11 Commissioning ATTENTION A Before starting the inverter commissioning procedure ensure that all the checks indicated in the previous sections of this Quick Installation Guide have been correctly perfo...

Page 7: ... server TAKE NOTE OF THE LINKS STEP 3 Set the Date Time and Time Zone STEP 4 Set the inverter grid standard and configure the input channels By clicking FINISH the wizard completes the configuration procedure after the settings are confirmed the inverter restarts ATTENTION A From the moment the grid standard is selected there will be 24 hours available to make any changes to the grid standard afte...

Page 8: ...n of the degree of environmental pollution for the external environment 3 Environmental category Outdoor Physical Specs Environmental protection degree IP 65 IP54 for cooling section Cooling system Forced air Dimensions H x W x D 750 mm x 1100 mm x 257 mm 29 5 x 43 3 x 10 12 Weight 70 kg 154 lbs SX version Mounting system Wall bracket horizontal support Overvoltage category according to IEC 62109 ...

Reviews: