5. List of supplied components
Available components for wiring box
Q.ty
ALARM and AUX relay (33) and RS485 (38) connectors (pre-installed on
communication and control board (28))
4
Remote ON/OFF connector
(37)
pre-installed on communication board
(28)
1
Two-hole gasket for M25 signal cable glands
(12)
and cap
2 + 2
Key tool for front covers quarter cam-lock
(05)
1
M8x16 hex bolt + M8 serrated lock washers to clamp the earth cable on the protective
earth point (ext.)
(10)
1 + 2
M10 hex nut + M10 serrated lock washers to clamp the earth cable on the protective
earth point (int.)
(25)
1 + 2
WARNING!
NRS 097-2-1:2017 (South Africa)
It is not intended to connect this Inverter to a network with an higher
Network Impedance.
Reference Impedance
Fault Level
0.156
1475
Total [ Ω ]
I_SC [ A ]
3.9
1018
X/R ratio
S_SC [kVA] (three phase)
South africa network standard label
1
Technical documentation
1
Available components for wiring box Standard and -S2 version only
Q.ty
MPPT input parallel bar
1
M6 screws with washer to clamp the MPPT input parallel bars
2
Available components for wiring box -SX, -SY, -SX2 and SY2 version only
Q.ty
Positive string fuses (gPV - 1000Vdc - 20A)
24
Fuse puller (secure touch)
1
Available components for power module
Q.ty
M6x20 junction screws
(32)
between wiring box and power module
2
M6 self-locking nut to clamp internal AC cables on AC interconnection board
(58)
3
M5 hex nut + M5 serrated lock washers to clamp the internal earth cable on PE
interconnection point
(64)
1 + 2
Available components for brackets
Q.ty
M8 bolts with washers for mechanically securing the half-brackets
2
M6 screws for mechanically securing the wiring box to the bracket
2