background image

Page 2 

 

DO 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T 

 

Use to pump bleach. 

 

Use to pump petroleum products such as diesel fuel,    
gasoline or kerosene 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

Troubleshooting the Pump: 

 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assembly is 

in the 'ON' position. "I" is the 'ON' position and 'O' is the 'OFF' 

position. 

 

Check for defective pressure switch. Make sure you are con-

nected to a good   12 volt power source. Make sure any on/

off switches are in the 'on' position.  Remove the cap to the 
pressure switch. Pull both red wires off of their terminals, and 

touch the two ends together. If your pump runs when you do 

this, your   pressure switch will need to be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

Pulsating flow (surging): 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective or dirty check valve. 

 

Check for defective pressure switch. 

GPM=Gallons Per Minute
PSI=Pounds per Square Inch
DC=Direct Current

Wetted Parts Housing:

Polypropylene

Diaphragm:

Santoprene

Liquid Temperature:

130° F max.

Pump Specifications

Current:

7.4 Amps @ 40 PSI

Check Valve:

Viton

Pump Model:  5277982 

Available Replacement Parts 

Replacement Pump:  5275088 

Includes:  1/2” MNPT Port Kit Fitting #5168832 
 

 

 

1/2” Hose Barb Port Kit Fitting #5168833 

Summary of Contents for High-Flo Gold Series

Page 1: ...ll come with adapters which will allow you to hook up to various plumbing configurations These fittings push into the ports of the pump and a slide mecha nism locks them into place Use flexible hose or tubing to connect to the inlet and outlet ports on the pump This minimizes stress on the pump head Never use rigid pipe connections Do not compress the feet Overtightening will reduce the ability to...

Page 2: ...pressure switch will need to be replaced Check the fuse Check for low voltage at the power supply Pump does not prime Check for air leaks in supply line Check for debris in the check valve assembly Check for defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Pulsating flow surging Check for defective pressure switch Check for...

Page 3: ...he Check Valve If you re experiencing little to no pressure or the pump is not priming and you ve checked your filter screen and it s clean you may need to clean the check valve Remove the head of the pump which is held on by about 6 7 screws The first piece inside the head of the pump is called a check valve it s the part responsible for building up pressure and pumping water solution through the...

Page 4: ...y you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 800 Stevens Port Drive Suite DD836 Dakota Dunes SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more informatio...

Reviews: