Fimco 530302 Owner'S Manual Download Page 2

Page 2

 

 

Troubleshooting the Pump

:

 

 

Motor does not run:

 

 

Check for loose wiring connection(s).

 

 

Make sure the 'ON/OFF' switch in the lead wire assembly is in the 
'ON' position.  “I" is the 'ON' position and 'O' is the 'OFF' position.

 

 

Check for defective pressure switch. Make sure you are connected to 
a good 

 

 12 volt power source. Make sure any on/off switches are in 

the 'on' position. Remove the cap to the pressure switch. Pull both 
red wires off of their terminals, and touch the two ends together. If 
your pump runs when you do this,  your pressure switch will need to 
be replaced.

 

 

Check the fuse.

 

 

Check for low voltage at the power supply.

 

 

Pump does not prime:

 

 

Check for air leaks in supply line.

 

 

Check for clogged strainer/filter.

 

 

Check for cracks in the pump housing.

 

 

Check for empty product supply.

 

 

DO 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer

 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter.

 

 

Use clean water for your spray mixture

 

 

Store inside a building when not in use.

 

DON’T

 

 

Use to pump bleach.

 

 

Use to pump petroleum products such as diesel fuel, 

 

 

gasoline or kerosene

 

 

Leave your pump sit with spray mixture in it for extended 
periods

 

 

Use dirty or 

Pulsating flow (surging):

 

 

Check for defective pressure switch.

 

 

Check for leaks in the discharge line.

 

 

Check for restriction in the discharge line.

 

 

Check for debris in nozzle orifice.

 

 

Discharge hose may be too long.

 

 

Check for clogged strainer.

 

 

Motor continues to run after discharge is shut off:

 

 

Check for empty product supply.

 

 

Check for open bypass valve. (if equipped)

 

 

Check for low voltage.

 

 

Check for leak in discharge line.

 

 

Check for defective pressure switch.

 

Pump Specifications

 

Current:

 

2.2 Amps @ 30 PSI

 

Check Valve:

 

Viton

 

Wetted Parts Housing:

 

Polypropylene

 

Diaphragm:

 

Santoprene

 

Liquid Temperature:

 

110° F max.

 

 

 

GPM=Gallons Per Minute

 

PSI=Pounds per Square Inch

 

DC=Direct Current

 

Pump Model:  5277980

 

Available Replacement Parts

 