Fimco 5302928 Owner'S Manual Download Page 5

Page 5 

 

*** The Sprayer should now be ready for use *** 

After your boom mount brackets are secured in place. 

Bolt the 7-nozzle boom in place with (2)  Square  

U-Bolts and (4) whiz nuts. 

 

A 1/2” socket or wrench is required for this step. 

 

Try to maintain  approximately 18-22 inches above  the 

items being sprayed, for optimal coverage. This is con-

sidered  where  the  nozzles  will  mount,  at  the  end  of 

these brackets. 

 

 

 

 

 

 

 

With the boom secured to the boom mount, the nozzle 

harness can now be attached. 

 

Attach the nozzle harness to the boom.  

 

Starting  with  the  center  nozzle,  center  the  nozzle  har-

ness  on  the  boom  and  then  work  out  to  the  ends  on 

both sides using the nozzle clamps, attach the harness 

to the boom as shown in DETAIL Clamp. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Af-

ter 

your nozzle harness is attached to the boom,  

attach the feeder hose with a hose clamp  to the center 

nozzle. 

 

Place the hose clamp over the end of the hose loosely. 

Slip  the  end  of  the  hose  over  the  hose  barb  on  the 

’CROSS’  fitting  on  the  nozzle  harness.  Use  a  twisting 

motion,  if  necessary,  to  get  the  hose  fully  onto  each 

barb. Bring the hose clamp to the connection point and 

tighten securely. 

 

 

Step 7 

Step 8 

Step 9 

DETAIL Clamp 

Summary of Contents for 5302928

Page 1: ...ant Nozzles with No Drip Check Valve Strainers 18 x 8 5 x 8 Turf Tires Multi Lid OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support represe...

Page 2: ...e 2 1 x 32 Axle Shaft Turf Tires Contents of your sprayer s carton LG 50 TRL PRO Tank Plumbing Pre Assembly Owner s Manual Tongue Assembly 7 Nozzle Boom Boom Mount Kit 5281303 Contents of Parts Bag 5281302 ...

Page 3: ...k connect already attached Assembling the tongue to the frame Locate the 2 bent clevis pins from the parts bag Slide the preassembled tongue into the receiver of the main frame and lock in place with one bent clevis pin securing with the clip See Detail A Insert the other bent clevis pin into the hole in the hitch and secure with clip Detail A Step 1 Step 2 Detail B Detail C Step 3 Locate axle 2 1...

Page 4: ...up to the tank Secure the holders in place Do Not Over Tighten Wrap the hose and slip in the handgun Install the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Step 4 Step 5 Step 6 Locate the 2 boom mount brackets 4 5 16 18 x 9 16 x 2 3 16 square u bolts and 8 5 16 18 hex whiz nuts Mount the boom mount brackets on the upright boom arms as shown You can position them as needed just be sur...

Page 5: ...ached Attach the nozzle harness to the boom Starting with the center nozzle center the nozzle har ness on the boom and then work out to the ends on both sides using the nozzle clamps attach the harness to the boom as shown in DETAIL Clamp Af ter your nozzle harness is attached to the boom attach the feeder hose with a hose clamp to the center nozzle Place the hose clamp over the end of the hose lo...

Page 6: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 7: ...e flow rate and spray distribution Water rinse and dry the tips before storing NOTE The wheels have grease zerks for bearings Once a year new grease a NGLI No 2 lithium grease should be added to each wheel WARNING Some chemicals will damage the pump valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump ...

Page 8: ...Clean and rinse your pump after each use with Fimco Tank Neutralizer Winterize your pump or sprayer by rinsing draining and running RV Antifreeze through it before storing for the winter Use clean water for your spray mixture Store inside a building when not in use DON T Pulsating flow surging Check for defective pressure switch Check for leaks in the discharge line Check for restriction in the di...

Page 9: ...Page 9 Exploded View LG 50 TRL PRO 5302928 See Next Page for Parts List Bulkhead Fittings See Boom Assembly Parts List Page 11 See Plumbing Detail Next Page ...

Page 10: ...es with an On Off shut off valve located just before the strainer You must make sure the valve is in the open position before using your sprayer Manifold Detail Plumbing Detail Parts List LG 50 TRL PRO 5302928 Intake Assembly ...

Page 11: ...ips and 20 spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction tech nology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance including acids as well as exceptional wear life Compact size to prevent tip damage Excell...

Page 12: ...provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information about this Limited Warrant...