Troubleshooting the Pump: 

 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assem-
bly is in the 'ON' position.  “I" is the 'ON' position and 'O' 

is the 'OFF' position. 

 

Check for defective pressure switch. Make sure you are 
connected to a good 12 volt power source. Make sure 

any on/off switches are in the 'on' position. 

 

Remove the cap to the pressure switch. Pull both red 
wires off of their terminals, and touch the two ends to-

gether. If your pump runs when you do this,  your pres-

sure switch will need to be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

 

Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

DO 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T 

 

Pulsating flow (surging): 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

 

Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective or dirty check valve. 

 

Check for defective pressure switch. 

 

Use to pump bleach. 

 

Use with Flammable or Combustible Liquids 

 

Store Flammable or Combustible Liquids 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

4.0 GPM Pump 

Model:  5151073 

Available Replacement Parts 

(Replacement Pump: 5281326) 

Summary of Contents for 5302926

Page 1: ...ss Sprayer Professional Grade Pump 4 0 GPM Ideal for Harsh Chemicals Oil Based Chemicals with Surfactants Long Range 13 PRO SERIES Handgun 38 Horizontal Spray 27 Vertical Roundup Ready OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Vi...

Page 2: ... sprayer s carton LG 3025 PRO 5302926 Contents of Parts Bag 5281292 Contents of Bracket Kit 5278138 Wet Boom Sub Assembly 5275712 Owner s Manual Tank Plumbing Pre Assembly End Nozzle 5275122 Pkg of 2 5275713 Multi Lid 5058200 ...

Page 3: ...and just hanging over the edge of the table or flat surface you are assembling this on Secure the boom mounting brackets to the tank mounting brackets with Cam handles as shown in Detail A You can position them as needed within the slot on the bracket Just be sure that the surfaces of both brackets are even with each other You are now ready to mount this unit to an ATV using ratchet straps NOT INC...

Page 4: ...placement End Nozzle Assembly Procedure For Boomless Wet Boom Your boom will come with the 2 end nozzle assemblies NOT affixed to your boom tube Follow the instructions below to attach these properly to the boom tube as shown Assembled End Nozzle 15 End Nozzle Information 5275122 This nozzle mounting stem Has a ratcheting motion Each click of the ratcheting motion is approx 15 For proper optimal s...

Page 5: ... unwrapping the spray wand hose from around the tank may be difficult Detail A Install the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Detail C Locate the handgun bracket grommet and screw from the parts bag and install onto the tank A phillips head screwdriver is required for this step Place the grommet in the bracket and then place a screw throug...

Page 6: ... the starting place for spraying When you are ready to spray turn the boom valve to the on position Detail A This will start solution spraying from the tips of the boom The pressure will decrease slightly when the boom is spraying Adjust the pressure by turning the ON OFF valve lever on the bypass line valve Detail B Make sure your pattern is sufficient You may down pressure the system by bypassin...

Page 7: ...ng of Cam Lock Mechanism Do not use QR bracket Cams to hold and store boom in vertical position Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than autom...

Page 8: ...Clean and rinse your pump after each use with Fimco Tank Neutralizer Winterize your pump or sprayer by rinsing draining and running RV Antifreeze through it before storing for the winter Use clean water for your spray mixture Store inside a building when not in use DON T Pulsating flow surging Check for defective pressure switch Check for leaks in the discharge line Check for restriction in the di...

Page 9: ...Page 9 Exploded View Parts List LG 3025 PRO 5302926 See Pump Manifold Detail Next Page See Boom Detail Page 11 for Breakdown Part Numbers ...

Page 10: ...Page 10 Pump Manifold Detail See Page 9 for Part Numbers 13 High Pressure Spray Gun w 3 8 Hose Barb 5163149 See Page 9 for Part Numbers ...

Page 11: ...i Lid and use calibration container to measure the correct amount of chemical for the water being used 3 Pour chemical into tank and tighten Multi Lid back onto tank If desired amount of water was added in step 1 you are done Be sure to press firm ly on fill cap to seal with Multi Lid If desired amount of water was not met in step 1 proceed to step 4 4 Open fill cap and place garden hose into tank...

Page 12: ... Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information about...

Reviews: