15
WEEKLY MAINTENANCE
15.
CLEANING THE SOLUTION TANK
1.
Check that the solution tank is empty, otherwise empty it by keeping the tap control lever operating
2.
Remove the water distribution pipe (1) from the hole on the brush head
3.
Disconnect the tie-rod (2) from the tap control lever (3)
4.
Remove the solution tank (see chapter "SOLUTION TANK") and clean it with a jet of running water
ATTENTION: you are advised to always wear protective gloves, to avoid the
risk of serious injury to your hands
1
3
2