background image

3

www.filtreco.nl

Introduction

Welcome to Filtreco: Filtration systems for koi ponds

Every koi lover knows the importance of good water quality. And that means having a good filtration 
system for your pond. To keep your water clear, the choice is clear: Choose Filtreco. We know how much 
you love your fish, and that is why we are the specialists that you can rely on. Your goal is to keep your 
water clean, clear and healthy for your fish. But for clean water, you must choose the right filtration 
system for your own specific situation. That's why Filtreco offers the widest selection of pond filters. 
All with an unparalleled level of service, the lowest risk of malfunction and easy installation. Make no 
mistake: when only the best quality will do, choose Filtreco. High-quality technology means quality of 
life for your koi.

It is clear.

Introduction

This is the user manual for the Combi drum 35 (pump).

By purchasing this Filtreco filter, you have made an excellent choice. Please read this user manual carefully 
before you start using this system. This will enable you to familiarise yourself with the system first. Any 
work carried out on or with this system must always be performed in strict accordance with this user 
manual.

To ensure safe, proper use, always adhere fully with the safety guidelines. Please keep this user manual 
in a safe place and transfer it to the new owner in the event that the system changes ownership.

Filtreco

Nusterweg 69
NL-6136 KT Sittard
The Netherlands

CoC 14052952
VAT NL 58.28.235.B01
Filtreco is a WTH B.V. brand.

IBAN: NL39RABO0136750729
BIC: RABONL2U

+31 46 457 25 55
[email protected]
www.filtreco.nl

Summary of Contents for Drum 35

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100331 User manual Combi drum 35 pump EN Order number ...

Page 2: ......

Page 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Combi drum 35 pump By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any wor...

Page 4: ......

Page 5: ...allations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical spec...

Page 6: ...still use the biological filtration segment The basin is fitted with a removable waste drain This can be removed from the interior of the drum which saves you the trouble of having to disassemble the drainage line The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away...

Page 7: ... For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers that...

Page 8: ... adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downward angle so that they can be fully emptied during the...

Page 9: ...plug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total output of 2500 W from pond pump and spare combi...

Page 10: ...p the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic and Manual...

Page 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must decrease the inflow capacity to the filter or increase the outflow capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible...

Page 12: ...ange Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an additio...

Page 13: ...e the drum check the seal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot with...

Page 14: ...14 Combi drum 35 pump 16 Technical diagram ...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P ...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...

Reviews: