Filtreco Drum 100 User Manual Download Page 8

8

drum 100 (pump)

6. Placement and setup 

If  you  plan  to  install  this  system  in  a  way  that  deviates 
significantly  from  the  recommendations  in  this  user  manual, 
allow for a specialist to inspect the installation to ensure that 
all technical specifications have been met.

The drum filter must always be placed in a level position. The 
bottom  of  the  filter  must  be  completely  supported.  It 
is  recommended to place the system on a flat cement floor. 
When positioning the filter, ensure that there is adequate space 
on all sides so that you have room to perform maintenance. In 
order for the filtration system to work properly, the filter must 
always be placed above the water level.

Any  greater  deviation  will  result  in  an  inaccurate  measuring 
of the water level. If the water level rises by more than 2 cm, 
the  water  will  overflow  via  the  duct  into  the  sewage  system. 
To prevent this, position the short electrode so that it is 1 cm 
below the surface on the upper side of the drain. To maintain a 
constant water level, you can install an automatic filling station 
with overflow function for your pond.

For  optimal  water  flow,  use  all  7  outlet  connections.  It  is 
recommended to use flexible rubber sleeves and joints when 
connecting  the  water  lines.  These  can  compensate  for  small 
differences in dimensions and also absorb vibration. 

Install slide valves or ball valves in front of and behind the filter, 
so that the filter can be emptied during maintenance.

Maintain  enough  distance  between  the  wall  and  the  drain  so 
that you can remove the drain.

The drainage duct can be connected to a sewage connection 
with a 110 mm diameter. Make sure that the duct is positioned 
at an adequate incline. It is recommended to install a pipe with 
a  flexible  rubber  sleeve.  These  can  compensate  for  small 
differences in dimensions and also absorb vibration. They can 
also be detached to remove the drainage duct.

Always use high-quality pipes with an adequate wall thickness.

Ideally, use 45 degree elbow connectors.

Lay the pipes at a downward angle so that they can be fully 
emptied during the winter to protect them against frost.

Note! Electrical shock hazard. Use of this electrical system or 
installation in connection with a (swimming) pond may result 
in severe injury or death.

Only use this system in accordance with national and regional 
regulations.

Always  use  suitable  transport  and  lifting  equipment  when 
transporting and assembling this system.

6.1  Connecting the control box

 

Ensure  that  the  control

  box  is  not  plugged  in  to  the  mains 

power supply! Open the control box!

Hang up the box on 4 screws aligned with the grooves on the 
back  of  the  box.  Space  between  the  holes  in  the  wall: 
w  =  280  mm x h= 251 mm. Remember that the length of the 
cable for the electrical equipment is 3 metres. Be careful when 
opening the box and remember that the screws you must loosen 
to open the door should not protrude when you turn the box 
open. The same goes for when you close the box.

6.2   Connecting the electrodes and water level meter

 

Ensure that the control

 box is not plugged in to the mains 

power supply! Open the control box!

Turn the gland caps on the underside of the box and slide them 
over  the  corresponding  cable.  Run  the  cable  through  the 
cable gland into the box, leaving adequate length. Then twist 
the gland caps closed again. Connect the electrodes as shown 
below using a suitable screwdriver. The labels on the electrodes 
match the codes on the connection inside the box.

Summary of Contents for Drum 100

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100309 User manual Drum 100 pump EN Order number ...

Page 2: ......

Page 3: ...hen only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 100 pump By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any work c...

Page 4: ......

Page 5: ...ations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical specifi...

Page 6: ...water to bypass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away any algae or other coarse particles...

Page 7: ...w For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers tha...

Page 8: ...sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downward angle so tha...

Page 9: ...ctors into the corresponding power sockets The plug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total ...

Page 10: ... or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic and...

Page 11: ...ether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must decrease the inflow capacity to the filter or increase the outflow capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible Check whet...

Page 12: ...ge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an additiona...

Page 13: ...e the drum check the seal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot with...

Page 14: ...14 Drum 100 pump 16 Technical diagram ...

Page 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P P ...

Page 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...

Reviews: