10
basic combi drum 25 (gravity)
8. Control box
The control box consists of a housing with:
•
2 power sockets, namely:
- Pump for the high-pressure submersible pump
- drum motor for the drum motor
•
3 buttons:
- Manual: for a manual flush cycle.
- Main Switch: to switch the power supply to the box on
and off.
- Reset: for replacing a fuse.
The control box also includes 2 cable glands for the power
supply cable and the throughput for the cable for the water
level meter.
9. Cleaning and maintenance
Note! Electrical shock hazard! This can result is severe injury
or death.
When performing cleaning and maintenance, always take the
following measures:
•
Always switch off the power supply and secure it from
being accidentally switched back on before you come into
contact with the water or perform any maintenance work
on the system.
•
General cleaning - 1x each month:
- Switch off the "Main switch" and unplug the system from
the mains power supply.
- Remove any coarse waste (such as algae) on the
inside of the drain.
- Clean the inside of the drum.
- Clean the water level meter electrodes.
•
Cleaning the sprayer heads - 2x per month:
- Remove the sprayer head by turning it to the left
to unscrew it from the quick-release fastener.
- Remove the gasket from the holder.
- Remove the right-angle sprayer from the connector.
- Clean it.
- Install the gasket and sprayer back into the holder.
- Turn the holder onto the clamp bracket.