basic combi drum 25 (gravity)

8. Control box

The control box consists of a housing with:

• 

2 power sockets, namely:

 

-  Pump for the high-pressure submersible pump

 

-  drum motor for the drum motor

• 

3 buttons:

 

-  Manual: for a manual flush cycle.

 

-  Main Switch: to switch the power supply to the box on  

 

  and off.

 

-  Reset: for replacing a fuse.

The  control  box  also  includes  2  cable  glands  for  the  power 
supply  cable  and  the  throughput  for  the  cable  for  the  water 
level meter.

9.  Cleaning and maintenance

Note! Electrical shock hazard! This can result is severe injury 
or death.

When performing cleaning and maintenance, always take the 
following measures:

• 

Always  switch  off  the  power  supply  and  secure  it  from 
being accidentally switched back on before you come into 
contact with the water or perform any maintenance work 
on the system.

• 

General cleaning - 1x each month:

 

-  Switch off the "Main switch" and unplug the system from  

 

  the mains power supply.

 

-  Remove  any  coarse  waste  (such  as  algae)  on  the 

 

  inside of the drain.

 

-  Clean the inside of the drum.

 

-  Clean the water level meter electrodes.

• 

Cleaning the sprayer heads - 2x per month:

 

-  Remove  the  sprayer  head  by  turning  it  to  the  left  

 

  to unscrew it from the quick-release fastener.

 

-  Remove the gasket from the holder.

 

-  Remove the right-angle sprayer from the connector.

 

-  Clean it.

 

-  Install the gasket and sprayer back into the holder.

 

-  Turn the holder onto the clamp bracket. 

Summary of Contents for 100286

Page 1: ...1 www filtreco nl It is clear www filtreco nl 100286 User manual Basic combi drum 25 gravity EN Order number...

Page 2: ......

Page 3: ...the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Basic combi drum 25 gravity By purchasing...

Page 4: ......

Page 5: ...nstallations 07 5 3 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjus...

Page 6: ...nables you to still use the biological filtration segment The second partition has slotted holes that allow the water to pass into the biological filtration chamber The basin is fitted with a removabl...

Page 7: ...For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications...

Page 8: ...nstall a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high qua...

Page 9: ...r The water level meter consists of 3 stainless steel electrodes The flush cycle off electrode the short coated electrode The low level flush cycle on electrode the long coated electrode The common el...

Page 10: ...ance always take the following measures Always switch off the power supply and secure it from being accidentally switched back on before you come into contact with the water or perform any maintenance...

Page 11: ...water pumps are connected Check whether the inlet or outlet is clogged Insufficient water flow Check whether the inlet or outlet is clogged There are not enough inlet connections installed The circul...

Page 12: ...12 Basic combi drum 25 gravity 14 Technical diagram...

Page 13: ...13 www filtreco nl 15 Diagram for assembly in a pond P...

Page 14: ...14 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand...

Reviews: