Filtration Group SilentCare Translation Of The Original Instructions Download Page 5

 

Page 5 

 

Translation of the original instructions, SilentCare room air filter, Filtration Group GmbH, 01.02.21, Mat. No. 72488984, Version 01 

 

 

Technical data 

 
 

 

  The room air filter is suitable for rooms up 

to approx. 45 

m

2

 (max. 70 

m

2

)

 in size 

(max. purification in booster mode). 

 

According to current RKI studies, with 5-
fold exchange (5 air changes per hour) 
and a room height of 2.5 m, 15 minutes 
without air purification mean an increased 
risk of infection.

 

 

 

Ambient temperature:.............................. +10°C to +40°C   
Noise level: ....................................................... 42 dB(A) 
Air flow: ..........................................  600 m

3

/h +/-50 m

3

/h  

 ........................................  (max. 900 m

3

/h +/-50 m

3

/h (1) 

Pressure: ................................................... Max. 18 mbar  
Material: .......... Sheet steel housing, powder-coated, grey 
Power [V]: .......................................... 220-240 V / 170 W  
Insulation [IP]: ............................................ IP20 / class 1 
 
Filter surface [m²]: .................................................. 15 m

2

 

Dimensions:  ...........  Height approx. 1100 mm, Ø 500 mm 
Weight:  ..................................................... Approx. 32 kg 

 

Transport and storage 

 

WARNING! 

Risk of injury if the equipment is tilted! 

  Do not install the room air filter on an uneven surface 

and be careful not to tilt it during transport. 

  Two people are required to transport the equipment! 

 

As-delivered condition 

  Completely assembled, packed and upright on a pallet. 

 

Storage 

  Always store in the original packaging. 

  Always store in a dry, frost-free room. 

 

Transport 

  Always transport upright on a pallet. 

  Do not remove the straps until the equipment reaches its 

place of use. 

  Separate the packaging material and dispose of it in an 

environmentally responsible way. 

 

Installing the room air filter 

 

 

WARNING! 

Risk of reduced efficiency! 

  The equipment should always be installed in a dry, 

frost-free environment! 

  The equipment is not suitable for outdoor use! 

 

 

WARNING! 

Danger of tripping! 

  Lock the casters at the place of use! 

  Lay the power cable so that no-one can trip over it! 

 

 

 

 

A minimum distance of 2 metres is required 
from the wall! 

 

  Ensure that the air outlet is unobstructed at all times. It 

must neither be closed nor altered. 

  Install the equipment such that the air and heat vents 

cannot be obstructed. 

 

 

9.1 

Electrical connections 

 

DANGER!

 

 

Danger of electric shock! 

  Risk of serious or fatal injury in case of 

contact with electrical components. 

 
 

 

The plug must be removed in order to 
disconnect the room air filter from the 
mains! 

 

 

 

The power cable must have the following 
fuse protection: 
Time delay 6.3 A / 250 V 

 
 

  Compare the data indicated on the name-plate with the 

values for the power supply system. 

  Avoid using extension cables. 

  Connect the plug to the mains. 

  The system is now ready for operation. 

 
 

Summary of Contents for SilentCare

Page 1: ...Translation of the original instructions SilentCare room air filter Mat No of original instructions 72488984...

Page 2: ...ell as in damage to the room air filter Failure of critical functions of the room air filter Danger to persons from electrical or mechanical effects as well as from chemical reactions Danger to the en...

Page 3: ...ury CAUTION Potentially dangerous situation Non observance can result in minor or moderate injuries CAUTION without a symbol Potentially dangerous situation Non observance can result in property damag...

Page 4: ...from such use 5 Foreseeable misuse No liability will be accepted by the manufacturer if the equipment has been modified as well as in the event of improper mounting installation start up operation ser...

Page 5: ...riginal packaging Always store in a dry frost free room Transport Always transport upright on a pallet Do not remove the straps until the equipment reaches its place of use Separate the packaging mate...

Page 6: ...output can shorten the service life of the filter element 11 Replacing the filter element DANGER Danger of electric shock when replacing the filter element Disconnect the equipment from the power sup...

Page 7: ...ion Group GmbH 01 02 21 Mat No 72488984 Version 01 WARNING The equipment may only be operated using the cable which is supplied with it 2 Disconnect the room air filter from the mains 3 Loosen the loc...

Page 8: ...Mat No 72488984 Version 01 6 Place the used filter element in the packaging provided for this purpose 7 Seal the packaging ready for disposal Disposal 8 Inspect the inside of the housing for dust fou...

Page 9: ...ain The system is now ready for operation 12 Repair DANGER Risk of injury to persons or damage to property in the event of improper repair All repairs must be carried out by the manufacturer 13 Dispos...

Page 10: ...Page 10 Translation of the original instructions SilentCare room air filter Filtration Group GmbH 01 02 21 Mat No 72488984 Version 01 14 Declaration of conformity...

Page 11: ...Filtration Group GmbH Schleifbachweg 45 D 74613 hringen Phone 49 7941 6466 0 Fax 49 7941 6466 429 industrial filtrationgroup com industrial filtrationgroup com 72488984 I01 02 2021...

Reviews: