Fluid Viscosity
The portable analysers are designed to handle a fluid viscosity of up to 460 cSt for the small unit or
2400 cSt for the larger units
. It’s possible to pass high viscosity oils through the unit if they are
preheated as per the below table.
Note that as a pre-heated oil passes though the unit it will cool, therefore increasing its viscosity and
strain on the pump.
Temperature
°C
Viscosity (cSt)
ISO 32
ISO 46
ISO 68
ISO 100 ISO 150 ISO 220 ISO 320 ISO 460 ISO 680
10.0
161
262
442
711
1185
1921
2911
4827
8042
12.0
141
227
379
605
1001
1611
2435
3991
6588
14.0
124
198
327
518
850
1358
2048
3318
5427
16.0
109
173
283
446
726
1150
1730
2774
4496
18.0
97
152
246
385
622
979
1469
2331
3745
20.0
86
134
215
334
536
838
1254
1968
3135
22.0
77
118
188
291
464
720
1074
1670
2638
24.0
69
105
166
255
403
621
925
1423
2230
26.0
62
94
147
224
352
538
799
1219
1894
28.0
56
84
130
198
308
469
694
1048
1616
30.0
51
75
116
175
271
409
604
905
1385
32.0
46
68
103
155
239
359
528
784
1192
34.0
42
61
93
139
212
316
464
683
1030
36.0
38
56
83
124
188
279
408
596
894
38.0
35
50
75
111
168
247
361
523
778
40.0
32
46
68
100
150
220
320
460
680
42.0
29
42
62
90
135
196
285
406
596
44.0
27
38
56
82
121
176
254
360
525
46.0
25
35
51
74
109
158
227
320
463
48.0
23
33
47
67
99
142
204
285
411
50.0
21
30
43
62
90
128
183
255
365
Internal Gear Pump
The internal gear pump provides a steady flow for accuracy of results. Fluids above the rated
viscosity can cause excess motor strain and cause it to overheat or slip.
It’s important to pay
attention to the grade of oil being analysed and its temperature.