English –
13
English
9.8 - CONNECTING THE 230 V LIGHT OUTPUT
230 V, 500 W max
31
To perform the connection see
Fig. 31
and consult the relevant instruction
manual.
9.9 - INSTALLING THE EXTERNAL RELEASE SYSTEM model KS200KIT
To install the KS200KIT external release system in the gearmotor, see
Fig. 32
and consult the relevant instruction manual.
1
2
3
4
5
1
2
2
3
1
2
3
1
2
1
01.
04.
02.
03.
05.
32
9.10 - DIAGNOSTICS AND DEVICE SIGNALS
Certain devices are configured to display messages to identify their operating status or any anomalies.
9.10.1 - Photocell signals
The photocells contain a SAFE led
(
Fig. 7
) that allows for verifying their operating status at any time: see
Table 6
.
TABLE 6
SAFE led (Fig. 7)
Status
Action
Off
The photocell is not powered or is
faulty
Check that the voltage on the photocell terminals is around 8–12 VDC; if the volt-
age is correct, the photocell is probably faulty
3 quick flashes and 1
second pause
Device not recognised by the control
unit
Repeat the recognition procedure on the control unit. Check that all pairs of pho-
tocells on the ECSBus have different addresses (consult the instruction manual of
the photocells)
1 very slow flash
The RX receives an excellent signal
Normal operation
1 slow flash
The RX receives a good signal
Normal operation
1 quick flash
The RX receives a poor signal
Normal operation but check TX-RX alignment and correct cleaning of photocell lenses
1 extremely fast flash
The RX receives a bad signal
At the limit of normal operation; check TX-RX alignment and correct cleaning of
photocell lenses
Always lit
The RX does not receive any signal
Check for any obstruction between TX and RX. Check that the Led on TX emits a
slow flash. Check the TX-RX alignment