![Fiessler BLVT Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/fiessler/blvt/blvt_operating-instructions-manual_2288061010.webp)
3.5
LED-displays
(also refer to chap.
6.2
and
6.3
Commissioning and Trouble-Shooting)
Several LEDs on the receiver indicate the current operating status (Fig. 10/1). If the system test detects an internal or external
fault, the machine will be switched off immediately and the LEDs on the receiver and/or transmitter (if the fault lies within the
transmittter) indicate the fault status to the user by quick flashing.
When a fault is present, the flashing LEDs together with a fault code provide visual output of the detected fault and display in the
diagnostics device.
3.6 Operating mode switches
The DIP switches in the connector cover enable the following operating modes to be selected:
- Safety mode with / without restart interlock
- With / without contactor check
- equivalent / antivalent outputs
(Fig. 9/1)
In the condition when delivered, the preset operating mode comprises safety mode with:
restart interlock,
contactor check
and
equivalent outputs
.
Caution!
The operating mode may only be selected when no voltage is present. If the DIP
switches are actuated during operation, the light barrier will switch off the outputs and
go to locking status. This is indicated by flashing of the yellow and orange LEDs. Locking status will only be ended
once the power supply has been switched off.
The switchgears ULSG, LSUW NSR 3-1-K and LSUW N1-Muting K are available for additional functions such as potential-free
output contacts or muting (Refer to Section 8 for further information and electric connection).
without contactor control
with contactor control
The operating mode with
contactor control
serves to monitor the
driven succeeding contactors.
After each interruption of the light path and before each release of
the switching outputs, it is checked whether the succeeding
contactors have fallen. Only then will a new release be possible. If
the contactors do not respond within 300 ms, the light barrier
switches off the outputs and goes into locking status.
without restart interlock
equivalent outputs
with restart interlock
antivalent outputs
With the operating mode with r
estart interlock
selected, a button
must be connected to the start button input for a start release of the
operating movement.
When the protective field is free, the yellow LED lights up on the
receiver as a start prompt. Only once the start button has been
pressed will the outputs of the ULVT/BLVT be switched to active.
In the
equivalent outputs operating mode
, both PNP outputs are
failsafe and monitored internally for short-circuits and cross-circuits.
With a free light path, both outputs are high (+24 V). In the
antiva-
lent outputs operating mode
, output 1 is high (+24 V) and output 2
low (0 V) when the light path is free.
Output 2 is not failsafe in this
operating mode. This operating mode is only permissible in
conjunction with the safety switchgears LSUW NSR 3-1K,
LSUW N1-Muting K, or another safe sequential phase control
device which monitors output 2!
3
System description
-
LED-displays/operation modes
Bild 10/2
The operating modes can be set
using the DIP switches.
The
condition when delivered is
shown here.
1 2 3 4 5 6
off
1 2 3 4 5 6
off
1 2 3 4 5 6
off
1 2 3 4 5 6
off
1 2 3 4 5 6
off
1 2 3 4 5 6
off
1 2 3 4 5 6
off
Table 10/3 programming of operation modes
Bild 10/1 LED indicate the operating and/or fault status
Receiver
Green ON
light barrier free
Red ON
Orange ON
light barrier interrupted
contamination
(no reserve)
Yellow ON
fast orange flashing
ca. 4 x /s
fast yellow flashing
ca. 4 x /s
slow orange flashing
ca. 1 x /s
Start prompt
fault
fault
BLVT only:
: reduced resolution
slow yellow flashing
ca. 1 x /s
BLVT only:
: reduced resolution
ULVTE Empfänger
Made in Germany
D-73734 Esslingen, Kastellstr.9
0711/91 96 97 -0
1
2
3
4
5
6
7
3
:OSSD2
6
: 0V
5
:
2
: EDM
7
: 24VDC
±20%
4
: OSSD1
1
: Start
ULVT Receiver/Récepteur
interdiction de
redémarrage
restart
interlock
adjustment
LC interrupt
LC free
Aide
d´àjustement
libre
interrompu
BWS Typ4, ESPE Type4 , ESPS Type4
FIESSLER
Wiederanlauf
Justierhilfe
LS
LS frei
unterbrochen
sperre
E L E K T R O N I K
outputs are fail safe
output 2 = not fail-safe!
Transmitter
Yellow ON
Transmitter active
Yellow OFF
Fast Yellow flas-
hing ca. 4 x /s
Transmitter off
fault
Slow Yellow flas-
hing ca. 1 x /s
cascading only:
succeeding recei-
ver: interrupted
Sender ein
Transmitter on
1
2
3
ULVT Sender
TÜV Rheinland
Made in Germany
D-73734 Esslingen, Kastellstr.9
0711/3 45 19 44
ULVT Transmitter/Emetteur
BWS Typ4, ESPE Type4, ESPS Type4
Emetteur en
marche
FIESSLER
E L E K T R O N I K
FIESSLER
E L E K T R O N I K
1
10
Fiessler Elektronik GmbH & Co. KG
Doku Nr. 958 Stand 22.01.2018 RK
Phone: +49 (0) 711 / 91 96 97-0 Internet: http://www.fiessler.de
Fax : +49 (0) 711 / 91 96 97-50 eMail: [email protected]