Warnings issued when several consecutive malfunctions occur that lead to an interlocking of the AKAS@
with displayed error reports. The interlocking status can be cancelled only by a voltage reset.
Electrical connections - Description / Wiring diagrams
Displaying outputs
39
Warnings (binary xxxxxx10)
error reports (binary xxxxxx01)
6
6.6
Warning
transferred
decim. by-
te
error
transfer-
red de-
cim.byte
operating mode
description
possible text in the display
system
reason for the error
6
6
5
5
no monitoring of the
protective circuit
EDM does not respond
even though the OSSDs
are released
-
I f this happens during fast sped: valve position
monitors do not switch in fast speed position
or at an interruption in the EDMS circuit.
I f this happens during Muting: EDMS and
EDMO are both at + 24 V
-
10
10
18
18
9
9
with additional
safety PLC
(e.g.
FPSC
)
17
17
overrun traverse
control
slow speed signal error
slow speed signal error
When switching over from fast speed into slow
speed, at SGO 24 V
When swithcing over vom fast speed into slow speed,
the triggereing of the SGS and the SGO is antivalent
instead of equivalent
machine stops at the
overrun traverse cam/
cam switch does not
conduct
-
in the case of "warning": open press comple-
tey, in the case of "error": check cable and
cam switch
-
30
86
86
90 / 102
29
85
85
89 / 101
no monitoring of the
protective circuit
106
106
114
126
105
105
with additional
safety PLC
(e.g.
FPSC
)
113
125
no complete slow speed
position in the Muting
status
Problem release of the
rear stoppers
This message is displayed when the stroke is
started in slow speed range or with a slow
speed request SGA = 0 and if there is no
complete switch-over of the slow speed posi-
tion monitors into slow speed. Check the SGA
line for interruptions and check also the slow
speed position monitors and their lines.
line short circuiting of one RXOX circuit with
another line
internal error
Problem fast speed --
slow speed request
if this is displayed again after the voltage re-
set, a verification by Fiessler Elektronik is ne-
cessary
line short circuiting of the SGA circuit with an-
other line
fast speed/slow speed
signals are faulty in
stop status
fast speed/slow speed
signals are faulty in
stop status
during operation without safety PLC, both
EDMS and EDMO are at + 24 V at the same
time in stopped status.
The triggering of the SGS and the SGO is antivalent
instead of equivalent
OSSD- error
short circuit of the the
muting lamp line
line short circuiting of the OSSD circuits with
other lines
only possible at the version with external Mu-
ting lamp, otherwise: internal problem
130
142
150
166
129
141
149
165
170
198
interlocking
without
prior war-
ning
interlocking
without
prior war-
ning
169
197
201
237
with additional
safety PLC
(e.g.
FPSC
)
problem at request for
higher switchover po-
int:
Muting lamp should not
light up, release box
bending button
line short circuiting of the HUSP circuit with ot-
her lines
short circuit in box bending button or line short
circuiting of the KAST circuit with other lines
problem at pressing of
foot pedal
Hex switches deadju-
sted
line short circuiting of the foot pedal circuits
FUO and FUS with other lines
Readjust the Hex switches onto the selected
operating mode, then carry out a voltage re-
set. I f the error repeats itself, a repair by
Fiessler Elektronik is necessary.
invalid Hex switch posi-
tion
external transmitter
signals are received
Turn HEX switch into a permitted position
The transmitter is triggered although the foot
pedal is released, or a transmitter from anot-
her AKAS® focuses the receiver. This must be
prevented by adequate constructional measu-
res.
unequal slow speed
connections
disable key switch -
voltage reset
This error happens only during the operating
mode "for connection to safety PLC" if the
signals at the SGO and the SGS are not
exactly the same.
The key switch ot the front reset switch have been ac-
tivated when the foot pedal was pressed, or there is
an error within the foot pedal, or the front reset button
does not close.
246
245
internal error
I f this message is displayed immediately after
a voltage reset, there is an EMC problem or an
internal failure of the appliance.
Doku Nr. 995 Stand 1.12.2011 / Aui
background grey: ((other
message or no message,
if monitoring functions are
partially cancelled)