INSTRUCTIONS FOR EASY ASSEMBLING AND CONNECTING NATURAL SURFACE HUMIDIFICATION SYSTEM
We are providing our MG & Astral series of a new practical humidification system delivered as a standard feature.
Humidification will be performed through a specially conceived basin with automatic constant level water flow
and external accumulation tank (fig. 1).
• Place the plastic reserve tank (packed inside the machine), on top of the machine
• Connecting the water inlet pipe (fig. 2)
• Fill with water the outside reserve tank, the water will go down into
the inside basin where the level will remain automatic by the float valve
• The inside water basin is equipped with automatic float valve to maintain
a constant water level
• In order to regulate the humidity value, utilize the metal cover included
VERY IMPORTANT (ORDINARY MAINTENANCE):
In order not to incur in any sudden water loss by the internal water tank please make sure that the floating does not present any malfunction that
may obstruct its movement. so keep the float perfecly clean and free of any lime deposit. after each incubation cycle put a solution of water 70%
+ white vinegar 30% inside the humidification tank for 2/3 hours. then disassemble the float, rinses it and reassemble it making sure of its correct
operation before a new use.
INSTRUCTIONS FOR EASY ASSEMBLING AND CONNECTION OF AUTOMATIC HUMIDITY FOR MODELS (optional)
OPTION 1
: HUMIDIFICATION BY ULTRASOUND: The air humidification inside the incubator is performed by a special humidifier (ultrasound nebuli-
zer) which uses ultrasound technology to atomize water & create a smoke effect without changing the operating temperature.
ULTRASOUND NEBULIZER ASSEMBLING AND PREPARATION: Remove the ultrasound nebulizer by its carton box and place it on a flat level surface
next to the incubator. Remove the humidifier plastic tank and fill it with water and then place it again up to plastic base. Connect the air injection pipe
to the humidifier inserting the aluminum disk fitted part on the humidifier column exit steam introducing then the opposite part of the same pipe for at
least 2-3 cm inside the special dedicated intake predisposed on the incubator.
OPERATION: Plug the humidifier power socket to the power outlet socket positioned on the control panel back side and switch on the humidifier by
selecting the option “ON” on the main switch ON/OFF. Adjust the steam injection flow intensity by the control knob on the frontal part of the humi-
difier. Generally it’s enough to keep the dial set to 60-70% but in case the settled humidity percentage is not reached than we suggest to turn the
knob to maximum position. A red light on the humidifier will warn about water shortage on the tank. The ultrasound nebulizer is driven by the LCD
control panel. After the above mentioned steps for connecting the instrument it’s necessary to set up the required humidity value in order to allow the
nebulizer automatic activation at each request of air humidification coming from the LCD thermostat.
IMPORTANT:
- The humidifier should be disconnected from any power outlet when filling the tank, during displacement and during cleaning
- The humidifier should not be used without water, if there is no water in the tank switch the humidifier off.
- Do not fill the humidifier tank with any other liquid than water, do not add medicines and do not cover any opening
- Do not use it outdoors
OPTION 2
: INTERNAL HUMIDIFICATION BY HOT WATER: By the option “Internal humidification by hot water” we have equipped the incubator with
an immersion resistance to be positioned inside the water tank; then connect the resistance, via the special plug, to the socket placed on the rear
of the control panel. The activation of the resistance will be piloted by the electronic control unit.
USE AND CALIBRATION:
Plug the incubator into the electric power and allow the machine to run at the correct temperature before
setting the eggs.
The thermostat, placed on the unit top, has been set-up by the factory see the information to the following paragraph “digital thermostat”.
Check that the set temperature on the thermostat dial agrees with the reading on the alcohol thermometer inside the incubator. 101°F for models
MG50 & MG 70 and 99,7°F for model MG 100. It’s important to check the temperature on the thermometer in the incubator.
The inside lighting of the machine is by a lamp activated by the switch placed on the control panel; remember to switch off the light while the
machine is in operation.
Once the temperature has reached the correct set-point, with ref. to the models MG70 and MG100
insert the trays with the eggs positioned correctly
2
; pay particular attention to connect in a proper
way the terminal part of the setting trays into the splits of the egg-turner bar; the egg turning device
will be activated automatically with the machine switching
3
.
Regarding the MG 50 it’s important to press the metal basket as shown in the picture 1 in order to
activate the egg-turning device. Remind that on the hatching period (last 2 days) it will be necessary
to stop the automatic turning simply bringing the tray back of about 1 cm (see picture 1).
Fig. 1
Fig. 2
Fig. 3
(Fig. 1)
ON EGG-TOURNING SWITCHING
OFF EGG-TOURNING SWITCHING
12