5.2
Client S ide Node Descriptors
Section Title
Nodes
Column Title
Function
Legal Values
Node_Name
Provide name for Node
Up to 32
alphanumeric
characters
Node_ID
VHLC station address of physical Server Node
1-255
Protocol
Specify protocol used
Genisys
Connection
Specify which port the device is connected to the
FieldServer
P1-P8
1
Genisys_Check_Controls*
If OFF, the FieldServer configures VHLC to apply controls
from the FieldServer without verification.
If ON, the FieldServer configures VHLC to verify controls
supplied by the FieldServer before applying.
OFF
, ON
Genisys_Intra_Poll_Delay*
Specify time, that FieldServer should wait before sending
ACK or Execute message after receiving the last character of
response from VHLC.
0.010s
, 0.025s etc
Example
// Client Side Nodes
//
Nodes
Node_Name , Node_ID , Protocol , Port , Genisys_Check_Controls , Genisys_Intra_Poll_Delay
Genisys_01
, 1
, Genisys , P1 , ON
, 0.01s
Genisys_02
, 2
, Genisys , P1 , -
, 0.01s