SPECIFICATIONS
Overrange:
"OL" mark indication.
Auto power off:
15 minutes.
Operating environment:
32
°
F (0°C) to 122
°
F
(50°C) at <75% R.H.
Storage temperature:
-4
°
F (-20°C) to 140
°
F
(60°C), 0 to 80% R.H. with battery removed.
Accuracy:
±0.03%rdg + 0.25oz (10g) 0 to 66lbs (0 to 30kg)
±0.05%rdg + 0.25oz (10g) 66 to 220lbs (30 to
100kg)
Resolution:
0.25 oz or 10g
Specifications good in ambient conditions of 73
°
F
±
9
°
F (23°C ±5°C), <75% relative humidity.
Temperature Coefficient:
0.1
×
(specified accuracy)
per
°
F.
Wireless Range:
33ft (10 meters)
Maximum load:
220 lbs (100kg)
Power:
Remote control: Single standard 9-volt bat-
tery, NEDA 1604, JIS 006P, IEC 6F22.
Platform: 6 x AA batteries
Battery life:
Remote control: 80 hours (continuous use) with
alkaline battery.
Platform: 100 hours (continuous use) with alkaline.
Weight (pl remote control):
7.1lbs (3.2kg)
Limited Warranty
This scale is warranted against defects in material
or workmanship for one year from date of purchase.
Fieldpiece will replace or repair the defective unit, at
its option, subject to verification of the defect.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising from the sale of a
Fieldpiece product, including but not limited to
implied warranties of merchantability and fitness for a
particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the
instrument or other incidental or consequential dam-
ages, expenses, or economic loss, or for any claim of
such damage, expenses, or economic loss.
State laws vary. The above limitations or exclu-
sions may not apply to you.
Obtaining Service
Call Fieldpiece Instruments for warranty service or
out of warranty pricing. Send check or money order
for the amount quoted. Send the meter freight pre-
paid to Fieldpiece Instruments. Send proof of date
and location of purchase for in-warranty service. The
scale will be repaired or replaced, at the option of
Fieldpiece, and returned via least cost transportation.
More from Fieldpiece
The SRS2 wireless refrigerant scale is designed for
HVAC/R technicians. Here are some other standalone
products from Fieldpiece Instruments.
SRH2
Diagnostic
Psychrometer
SC77
All-in-one Expandable
Clamp-on Meter
SSX34
Superheat and
Subcooling for A/C
and Refrigeration
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
ATM
ON/OFF
TYPE
TEMP.
UNIT
K
SH
SC
PRESS FOR 1 SECOND
AUTO-OFF
BATTERY
CHECK
Temp Cal
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
OUTPUT
T2
T
T
T
T
T
T
T
T
T2
T2
T2
T2
T2
T2
T2
T2
T2
2
2
2
2
2
2
2
2
T2
T2
T2
T2
T2
T2
T2
T2
T
T
T
T
T
T
T
T
ENTER
T2
T2
T2
T2
T2
T2
T2
T2
T2
ON/OFF
MAX/MIN/H
ON/OFF
RH/DP/WB/DB
T2
O
O
O
O
O
O
O
N
N
N
N
N
N/
/
/O
O
O
ON
ON
ON
ON
T
T
T
T
T
T
T
T
T
T
T2
OFF
O
O
O
O
N/
N/
N/
N
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
O
O
O
O
FF
FF
FF
FF
FF
O
O
O
O
/O
/O
/O
/O
2
2
2
2
2
2
2
2
2
2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T
T
T
T
T
T
T
T
T
T
TSH/TEET/NORM
SENSOR
SRH2
PRESS FOR
1 SECOND
AUTO-OFF
BATTERY
CHECK
T/C
Cal
°C
°F
T/C
NTC
Diagnostic
Psychrometer
Calculates
Target SH
and Target
Evap Exit
Temperature
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
PEAK
MUTE
ON/OFF
ON/OFF
L/M/H
SENSITIVITY
H
M
L
PEAK
LOW-BATT
PRESS FOR
1 SECOND
SRL2
Infrared
Refrigerant
Leak Detector
400
DISCONNECT
TEST LEADS
340
SC77
µ
Auto
4000m
400m
HOLD
NCV
m A K M
Ω
m V V
APO HOLD n m m F
AC
DC
SRL2
Infrared Refrigerant
Leak Detector
ANC3
Briefcase Style
Carrying Case
ATC1
K-type Thermocouple
Pipe Clamp