background image

Use data to create tell-all charts

The chart on the right was taken directly from the

data sent from the Data Logger. Once saved, you
can open  the file with any spreadsheet supporting
.xls format, including Microsoft Excel, and edit any
way you like. The chart on the right is exactly how it
looks after placing into a spreadsheet, adjusting col-
umn width to fit, and adding borders to the cells.

The sheet has 6 headings. The Reading heading

is the mV value recorded. The X1 is the value you
select as the MULT. The Type is the PARAM you
select to label the reading. The MAX/MIN shows the
maximum and minimum reading for that data set.
The AVG heading shows the running average for that
data set. A new data set is created when the rotary
dial position is changed.

The DL3 can be used to make reports showing a

wide range of applications all on one chart. In Data
Set 1, 10 temperature readings were taken using the
Sling Psychrometer Head (ARH4). You can just
leave it on its own taking measurements at any inter-
val, here every hour. 

Data Set 2 shows how the DL3 can be used with

the Anemometer Head (AAV3) to take a 3x3 reading
of a ventilation hood. These were manual recordings.
Notice here how the PARAM was changed to f/m to
represent feet/minute and the MULT was changed to
X100 to let you know the readings were multiplied by
100. Each accessory head will say in its instructions
whether or not the value recorded needs to be multi-
plied and what to multiply by.

Data Sets 3 through 7 show how, when you need

to record multiple parameters to evaluate a system,
you can just take a reading, change the PARAM, and
each measurement will be shown in its own data set
with their own label (PARAM) since they aren’t relat-
ed. These five parameters were part of an air

conditioning system evaluation. Here, the user chose
outdoor air temp to be represented by oFa, wet bulb
as WB, suction line temp outside as STo, suction line
temp inside as STi, and liquid line temp as LLT.
These are just arbitrary labels. Set them to whatever
makes the most sense for the job you’re doing.

Date

Time

Reading Type MAX/MIN AVG

Data Set1

X1

2/6/2002 02:20:25AM

75.65 oF 

75.65

2/6/2002 03:20:25AM

75.66 oF 

75.65

2/6/2002 04:20:25AM

75.61 oF 

75.64

2/6/2002 05:20:25AM

75.67 oF 

75.65

2/6/2002 06:20:25AM

75.87 oF 

75.69

2/6/2002 07:20:25AM

76.17 oF 

75.77

2/6/2002 08:20:25AM

76.25 oF MAX1

75.84

2/6/2002 09:20:25AM

76.22 oF 

75.89

2/6/2002 10:20:25AM

75.9 oF 

75.89

2/6/2002 11:20:25AM

75.09 oF MIN1

75.81

Data Set2

X100

2/6/2002 11:23:25AM

142 f/m

142

2/6/2002 11:23:29AM

98 f/m

120

2/6/2002 11:23:34AM

173 f/m

MAX2

138

2/6/2002 11:23:44AM

121 f/m

133

2/6/2002 11:23:49AM

145 f/m

136

2/6/2002 11:23:53AM

138 f/m

136

2/6/2002 11:23:59AM

106 f/m

132

2/6/2002 11:24:01AM

96 f/m

127

2/6/2002 11:24:05AM

88 f/m

MIN2

123

Data Set3

x1

2/8/2002 01:56:19PM

76.08 oFa MIN4

76.08

Data Set4

x1

2/8/2002 02:47:25PM

54.36 WB MIN5

54.36

Data Set5

x1

2/8/2002 02:59:39PM

25.36 STo MIN6

25.36

Data Set6

x1

2/8/2002 03:33:04PM

72.42 STi

MIN7

72.42

Data Set7

x1

2/8/2002 03:42:32PM

46.45 LLT MIN8

46.45

Install the software

The software links the DL3 to your PC. Once

installed you can upload and save data to a .xls file
which can be opened and edited in most spread-
sheets programs.

1. Insert CD, but do not install just yet.
2. Connect the included USB cable to the USB port

on your PC. Connect the other end of the cable
to bottom of DL3.

3.

"Welcome to the New Found Hardware Wizard"

bubble pops up in the taskbar. Click anywhere on
the bubble.

4. “

Can Windows connect to Windows Update to

search for software?”

window appears. Choose:

“No, not this time.”

Click Next.

5. “

What do you want the wizard to do?”

window

appears. Choose:  

“Install from a list or specific

location (Advanced)”. 

Click Next.

6.

“Search for the best driver in these locations.”

window appears. Check:  

“Search removable

media (floppy, CD-ROM...)”

Click Next.

7. Click Finish.
8. If the 

“Welcome to the Hardware Update Wizard"

window shows again, repeat steps 4-7.

9. Open the CD contents through My Computer and

run the “Setup.exe” or “Setup” file (the file with
the computer icon).

10. Follow the onscreen instructions to finish install.
11. Turn the dial to the SEND position; DL3 turns on.
12. Double click the yellow DL3 PC Utility icon on the

desktop to run software.

13. When asked, be sure to click and highlight the

date format you want to use and click OK.

14. As the program starts it automatically searches

for the DL3. If the DL3 was off or not connected
to the PC, you will need to restart the software
with the DL3 connected and set to READ/SEND.

15. Click “Start” on the software screen to begin. Set

rotary dial to READ/SEND. Press the Send but-
ton on the DL3 when asked. When it finishes
uploading, you can click on File to save data as
.xls so you can later open the file in your spread-
sheet. Remember where you save it so you can
open it later. The default save folder is c:\the
desktop\dl3 pc utility.

Connect to PC with USB cable

Once the software is installed, you can upload the

data and manipulate it to fit your needs in any
spreadsheet. To set up the DL3 for transferring data
to computer, first set range to READ/SEND. Then
connect the included USB cable from the bottom of
the DL3 to the USB port on your computer. Press the
SEND button to transfer data.

Troubleshooting

If problems with uploading the data from the DL3

to your computer occur, the drivers may need to be
updated.  Plug the DL3 into the computer and follow
these steps.

1. Right-click the My Computer icon on your desk-

top.  Choose: Properties.

2. Click the Hardware tab, then Device Manager.
3.  Find the section Ports (COM & LPT).  Expand this

section by pressing the [ + ] symbol.

4. Right click USB Serial Port (COM3). Choose

Update driver...

5. With the DL3 CD in the drive, follow steps 4-7 in

the “Install the software section” of this manual.
Repeat step 8, if necessary.

SPECIFICATIONS

Display:

4½ digit liquid crystal display (LCD) with a

maximum reading of 19999.

Memory: 

Up to 20,000 data points. Saved data is not

lost when replacing battery.

Overrange:

"OL" mark indication.

Zero:

Automatic.

Operating environment:

32°F to 122°F at <70%

R.H.

Storage temperature:

-4°F to 140°F, 0 to 80% R.H.

with battery removed.

Accuracy:

Stated accuracy at 73°F ±9°F, <75% rel-

ative humidity.

Temperature Coefficient:

0.1 × (specified accura-

cy) per °F/°C. (32 to 64°F (0 to 17°C); 82 to 122°F
(28 to 50°C)).

Power:

6 single 1.5-volt AA batteries.

Battery life:

1000 hours typical with alkaline.

Accessories:

One optical to USB pc cable, pc soft-

ware CD, six 1.5V AA batteries (installed), and
operating instructions.

Safety:

CE-EMC

DC volts

Ranges:

200mV, 2000mV

Resolution:

0.01mV

Accuracy:

±(0.1% rdg + 3 dgt)

Input impedance:

10M

Ω

Overload protection:

30VDC or 24VAC

AC volts (50Hz - 500Hz)

Ranges:

200mV, 2000mV

Resolution:

0.01mV

Accuracy:

±(1.2% rdg + 10 dgts)

Input impedance:

10M

Ω

Overload protection:

30VDC or 24VAC

Limited warranty

This meter is warranted against defects in materi-

al or workmanship for one years from date of pur-
chase. Fieldpiece will replace or repair the defective
unit, at its option, subject to verification of the defect.

This warranty does not apply to defects resulting

from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.

Any implied warranties arising from the sale of a

Fieldpiece product, including but not limited to
implied warranties of merchantability and fitness for a
particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the
instrument or other incidental or consequential dam-
ages, expenses, or economic loss, or for any claim of
such damage, expenses, or economic loss. 

State laws vary. The above limitations or exclu-

sions may not apply to you.

Obtaining service

Call Fieldpiece Instruments for one-price-fix-all

warranty service pricing. Send check or money order
for the amount quoted. Send the meter freight pre-
paid to Fieldpiece Instruments. Send proof of date
and location of purchase for in-warranty service. The
meter will be repaired or replaced, at the option of
Fieldpiece, and returned via least cost transportation. 