OPERATING INSTRUCTIONS
SYSTEM AIR PURGE PROCEDURE
1. Turn release valve counterclockwise
one full turn to the open position.
2. Rapidly pump the handle 6-8 times.
Leave handle in down position to
expose oil fill plug.
Remove cover plate.
3.
5. Replace cover plate and the jack is now
ready for use. Check for proper pump
action.
Screwdriver
Cover Plate
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to remove any air that may have been
introduced into the hydraulic system as a result of product shipment and handling.
This step is to be completed without any weight on the jack.
4. With a flat blade screwdriver, push
the oil fill plug slightly to the side to
purge trapped air from system. (Use
caution not to tear or puncture the oil
plug.)
HYDRAULIC FLOOR JACK