Preventative Maintenance
for SCL 800 preventative maintenance. All
basic maintenance and cleaning guidelines are applicable as well as the
following items specific to the SCL 800:
•
Monthly
1.
Note step count
2.
Test Remote Motion Controls (RMC)
3.
Clean and test obstruction sensor
•
Quarterly
1.
Inspect steps, step shafts, and bearings
2.
Inspect primary drive chain tension
•
Annually
1.
Inspect sprockets
2.
Inspect step chain and chain master link. Adjust chain tension as needed.
3.
Clean step chain with soft brush and vacuum
Active Status Light
The Active Status Light works similarly to the ASL on the EFX 800. The
brightness can be adjusted and the ASL can be set to off if that is desired.
Located on the right lower corner of the unit, the ASL has the same color status
pattern as on other ASL equipped units. There are four supported states:
1.
Solid blue
- indicates normal operation
2.
Pulsing blue
- indicates preventative maintenance is required
3.
Solid yellow
- indicates an error has occurred but the machine is useable
4.
Pulsing yellow
- indicates a loss of major function was detected.
The Maintenance Counter will cause the ASL to flash blue after 1,100,000 steps.
The current maintenance step count can be found in the information
maintenance menus under
MAINTENANCE COUNTER
.