Field Controls UV-Aire 46511500 Instruction Manual Download Page 6

page 6

WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire Air Purifying System out of the plenum

. Avoid touching the glass portion of the lamp with your hands.

MAINTENANCE

WARNING:

  Always unplug unit from the electrical outlet before commencing inspection and cleaning.

NOTE:

 Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of    

 

           accidental breakage of glass.

We recommend inspecting and cleaning the lamp at least every 6 months. Frequency depends upon the 

1. 

environment. Such as: the type of air filter, duration of use and replacement cycle.
To maintain maximum output intensity, replace the UV-Aire lamp 

2. 

annually. The lamp should operate continuously for maximum lamp life 

and light effectiveness.

REPLACEMENT PROCEDURE

WARNING: 

 Unplug unit from the electrical outlet before starting  

replacement procedure.

NOTE:

  Wear disposable, non-absorbent protective gloves prior to 

replacement procedure in case of accidental breakage of glass.

Rotate the UV-Aire ballast assembly counterclockwise until it stops.  

1. 

(See Figure 9)
Remove the ballast assembly and lamp from the mounting base.  

2. 

(See Figure 7)
Remove the lamp from the lamp socket. (See Figure 6)

3. 

Install the replacement lamp into lamp socket. Do not handle the lamp with 

4. 

bare hands. Oils on the hands tend to reduce lamp intensity.
Wipe off the glass with the supplied alcohol wipe.

5. 

Position the ballast assembly power cord 90° to the viewport hole on the 

6. 

mounting base. (See Figure 9)
Slide the lamp though the hole in the mounting base. (See Figure 7)

7. 

Press the ballast against the mounting base. Rotate the ballast assembly clockwise until it stops and is 

8. 

locked in place. (See Figure 10)
After assembly is firmly in place, plug the power supply cord back into the standard electrical outlet. 

9. 

Check lamp operation by looking through the viewport hole. A blue glow should be seen in the duct.
After replacing the lamp, make sure to install the Lamp Replacement Label. Print the date on the label 

10. 

and apply to the side of ballast assembly.

NOTE:

  If blue light leaks through any portion of plenum and/or around mounting plate, unplug power    

 

    supply cord immediately and seal affected areas and/or rotate ballast and repeat step #8 above.

UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local 

11. 

waste management authority for local disposal or recycling requirements. According to the EPA's 

Universal Waste Rule, these types of lamps may be disposed of into household waste. 

 

WARNING:

 Never touch broken lamp or internal contents of lamp. The lamp contains mercury.

 

NOTE:  In case of accidental exposure to internal contents of lamp, wash hands and any other affected skin area with 

mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical attention immediately.

Figure 9

Figure 10

Summary of Contents for UV-Aire 46511500

Page 1: ...for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION Installation Date Installed By Phone UV AIRE AIR PURIFYING SYSTEM Model UV 16 120 The UV Aire unit is designed to emit powerful UVC band light rays which sterilize and redu...

Page 2: ...and lamp for damage Do not install 0 this unit if any damage is noticeable If lamp is damaged cracked or broken do not touch 0 lamp or other contents in carton Close carton and return to seller immediately In case of accidental exposure to internal contents of lamp wash hands and any other 0 affected skin area with mild detergent Remove affected clothing immediately If skin surface 0 is pierced se...

Page 3: ...ATION Locate a suitable location for the unit 1 downstream from the A coil in the supply plenum or in the return plenum preferably downstream from the air filter For optimum cleaning effect on the A coil mount the unit in the supply plenum as close as possible to the A coil See Figure 1 CAUTION Investigate and determine the location of the A coil prior to drilling holes in duct for mounting unit N...

Page 4: ...ate See Figure 3 Using a 5 1 4 to 1 2 drill bit drill a viewport hole as indicated on the template See Figure 3 Optional Light Shield The light shield may be mounted at virtually any angle However when 6 deciding on a suitable location the mounting screw head can not be in the shaded area of template See Figure 4 Press shield onto duct wall then secure with screws See Figure 5 7 Attach the UV Aire...

Page 5: ...lockwise 90º Do not wire the unit into the appliance fan circuit Premature 12 failure of the ballast and lamp will occur The warranty will be voided Plug the power supply cord into a standard 120VAC electric outlet Check lamp operation by looking through the viewport hole NOTE The viewport hole is made of glass and will not allow any UVC rays to pass through A blue glow should be seen in the duct ...

Page 6: ...re hands Oils on the hands tend to reduce lamp intensity Wipe off the glass with the supplied alcohol wipe 5 Position the ballast assembly power cord 90 to the viewport hole on the 6 mounting base See Figure 9 Slide the lamp though the hole in the mounting base See Figure 7 7 Press the ballast against the mounting base Rotate the ballast assembly clockwise until it stops and is 8 locked in place S...

Page 7: ...ment authority for local disposal or recycling requirements 4 According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste Wash hands and remove and wash clothes for added safety measures 5 For replacement parts contact Field Controls at Phone 1 252 522 3031 Fax 1 252 522 0214 Email sales fieldcontrols com LAMP Replacement Part Number 46511200 TROUBLESHO...

Page 8: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...

Reviews: